All MIBs › CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB › cucsEquipmentFanModuleDefFanCapacity
cucsEquipmentFanModuleDefFanCapacity
Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleDefFanCapacity
OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.84.1.5
Node type: OBJECT-TYPE
Type: Gauge32
Access: read-only
Description: Cisco UCS equipment:FanModuleDef:fanCapacity managed object property
What is cucsEquipmentFanModuleDefFanCapacity?
This reports the rated airflow/cooling capacity of the fan module type defined by this record, per the FanModuleDef fanCapacity property. This spec is what an admin compares between two fan module options when deciding whether to upgrade to a higher-airflow module for a chassis running hot due to dense blade population. A fanCapacity value that's meaningfully higher on a newer fan module definition than on the currently installed model is the concrete case for a proactive fan module upgrade in a thermally stressed chassis.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.84.1.5 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleDefFanCapacity
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.84.1.5.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleDefFanCapacity.1
Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanModuleDefFanCapacity OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.15 | cucsEquipmentObjects | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.84 | cucsEquipmentFanModuleDefTable | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.84.1 | cucsEquipmentFanModuleDefEntry | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.84.1.5 | cucsEquipmentFanModuleDefFanCapacity | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |