CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentFanFanSpeedPolicyAdminState

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentFanFanSpeedPolicyAdminState

cucsEquipmentFanFanSpeedPolicyAdminState

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanFanSpeedPolicyAdminState

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.12.1.21

Node type: OBJECT-TYPE

Type: CucsPowerFanSpeed

Access: read-only

Description: Cisco UCS equipment:Fan:fanSpeedPolicyAdminState managed object property

What is cucsEquipmentFanFanSpeedPolicyAdminState?

This reports the administratively configured fan-speed policy setting applying to this fan, per its fanSpeedPolicyAdminState property, for example low, balanced, high-power, or max. This is the setting an admin actually chooses to trade off acoustic noise and power draw against cooling headroom for a chassis, and it's what to check first if a chassis seems louder or runs hotter than expected compared to a similarly configured one. An adminState of 'high-power' versus 'balanced' on two otherwise identical chassis explains why one runs its fans audibly faster than the other.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.12.1.21
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanFanSpeedPolicyAdminState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.12.1.21.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanFanSpeedPolicyAdminState.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentFanFanSpeedPolicyAdminState OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.12cucsEquipmentFanTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.12.1cucsEquipmentFanEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.12.1.21cucsEquipmentFanFanSpeedPolicyAdminStateCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB