CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentComputeConnServerSiocConnectivity

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentComputeConnServerSiocConnectivity

cucsEquipmentComputeConnServerSiocConnectivity

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentComputeConnServerSiocConnectivity

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.223.1.4

Node type: OBJECT-TYPE

Type: CucsEquipmentServerSiocConnState

Access: read-only

Description: Cisco UCS equipment:ComputeConn:serverSiocConnectivity managed object property

What is cucsEquipmentComputeConnServerSiocConnectivity?

This reports the current connectivity state between this compute node and its chassis SIOC — the Server I/O Controller module that links a blade or M-Series cartridge to the chassis's shared fabric uplinks — per the ComputeConn serverSiocConnectivity property. This is the specific value an admin checks when a server appears to have lost network or storage reachability despite the fabric interconnect itself looking healthy, since it isolates whether the fault is in the blade-to-SIOC link specifically rather than further upstream. A serverSiocConnectivity value reporting only one of two expected SIOC paths as up is the concrete evidence of a degraded, non-redundant connection for that specific server, even though it hasn't fully lost connectivity.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.223.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentComputeConnServerSiocConnectivity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.223.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentComputeConnServerSiocConnectivity.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentComputeConnServerSiocConnectivity OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.223cucsEquipmentComputeConnTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.223.1cucsEquipmentComputeConnEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.223.1.4cucsEquipmentComputeConnServerSiocConnectivityCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB