CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentComputeConnPolicyServerSiocConnectivity

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentComputeConnPolicyServerSiocConnectivity

cucsEquipmentComputeConnPolicyServerSiocConnectivity

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentComputeConnPolicyServerSiocConnectivity

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.224.1.9

Node type: OBJECT-TYPE

Type: CucsEquipmentServerSiocConnState

Access: read-only

Description: Cisco UCS equipment:ComputeConnPolicy:serverSiocConnectivity managed object property

What is cucsEquipmentComputeConnPolicyServerSiocConnectivity?

This is the required SIOC connectivity level enforced by this policy, per the ComputeConnPolicy serverSiocConnectivity property — for example requiring both SIOC paths versus tolerating just one. This is the actual setting that determines whether UCS Manager raises a fault when a server assigned to this policy loses one of its two SIOC links, versus treating a single-path connection as acceptable. Setting this to require both paths on a policy attached to production blades means a single failed SIOC link there will raise a fault, whereas the same failure on a blade under a looser policy would not.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.224.1.9
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentComputeConnPolicyServerSiocConnectivity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.224.1.9.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentComputeConnPolicyServerSiocConnectivity.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentComputeConnPolicyServerSiocConnectivity OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.224cucsEquipmentComputeConnPolicyTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.224.1cucsEquipmentComputeConnPolicyEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.224.1.9cucsEquipmentComputeConnPolicyServerSiocConnectivityCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB