CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentChassisStatsHistChassisI2CErrorsMax

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentChassisStatsHistChassisI2CErrorsMax

cucsEquipmentChassisStatsHistChassisI2CErrorsMax

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentChassisStatsHistChassisI2CErrorsMax

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.11.1.23

Node type: OBJECT-TYPE

Type: Unsigned64

Access: read-only

Description: Cisco UCS equipment:ChassisStatsHist:ChassisI2CErrorsMax managed object property

What is cucsEquipmentChassisStatsHistChassisI2CErrorsMax?

This is the archived peak I2C error count for the chassis within that historical interval, per the ChassisStatsHist ChassisI2CErrorsMax property. A historical spike in this max value that lines up with a maintenance date, like a fan or PSU swap, is how an admin confirms a physical hot-swap event, not a chronic fault, caused a specific past error burst. ChassisI2CErrorsMax of 60 in one archived interval that coincides with a logged PSU replacement supports that explanation rather than an unexplained hardware fault.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.11.1.23
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentChassisStatsHistChassisI2CErrorsMax

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.11.1.23.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentChassisStatsHistChassisI2CErrorsMax.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentChassisStatsHistChassisI2CErrorsMax OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.11cucsEquipmentChassisStatsHistTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.11.1cucsEquipmentChassisStatsHistEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.11.1.23cucsEquipmentChassisStatsHistChassisI2CErrorsMaxCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB