All MIBs › CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB › cucsEquipmentChassisFsmRmtInvRslt
cucsEquipmentChassisFsmRmtInvRslt
Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentChassisFsmRmtInvRslt
OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.7.1.15
Node type: OBJECT-TYPE
Type: CucsConditionRemoteInvRslt
Access: read-only
Description: Cisco UCS equipment:Chassis:fsmRmtInvRslt managed object property
What is cucsEquipmentChassisFsmRmtInvRslt?
This reports the result classification of the last remote invocation made during this chassis's FSM workflow. UCS Manager uses this classification to decide whether to auto-retry the failed step (for a transient network blip) or mark the chassis's operation as failed outright, so it is a direct input into whether the admin needs to intervene manually. A value of 'invocation-timed-out' would explain why a chassis discovery seems to hang without ever explicitly erroring.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.7.1.15 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentChassisFsmRmtInvRslt
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.7.1.15.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentChassisFsmRmtInvRslt.1
Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentChassisFsmRmtInvRslt OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.15 | cucsEquipmentObjects | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.7 | cucsEquipmentChassisTable | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.7.1 | cucsEquipmentChassisEntry | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |
| 1.3.6.1.4.1.9.9.719.1.15.7.1.15 | cucsEquipmentChassisFsmRmtInvRslt | CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB |