CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB :: cucsEquipmentBreakoutCapPolicyOwner

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIBcucsEquipmentBreakoutCapPolicyOwner

cucsEquipmentBreakoutCapPolicyOwner

Module: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentBreakoutCapPolicyOwner

OID (numeric): 1.3.6.1.4.1.9.9.719.1.15.159.1.9

Node type: OBJECT-TYPE

Type: CucsPolicyPolicyOwner

Access: read-only

Description: Cisco UCS equipment:BreakoutCap:policyOwner managed object property

What is cucsEquipmentBreakoutCapPolicyOwner?

This indicates who or what owns the policy settings applied to one port breakout capability record, which describes whether a specific fabric-interconnect or switch port can be split into multiple lower-speed ports (for example one 40G QSFP port broken into four 10G ports) -- typically whether the value comes from a local definition, an inherited policy, or UCS Central (the multi-domain policy owner). This matters operationally because a breakout capability record whose policyOwner is 'policy' rather than 'local' cannot have its settings changed directly at the domain -- an admin has to go edit the org-wide policy or UCS Central definition instead, or their local change will be silently overwritten on the next sync. A value of 'local' means the setting was configured directly in this UCS Manager domain; a value of 'pending-policy' would mean a change is queued from UCS Central but not yet applied.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.159.1.9
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentBreakoutCapPolicyOwner

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.15.159.1.9.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentBreakoutCapPolicyOwner.1

Start monitoring Cisco UCS chassis, blade/rack servers, fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB::cucsEquipmentBreakoutCapPolicyOwner OID value, configure state conditions and alerts, and monitor any Cisco UCS chassis, blade/rack servers, fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.15cucsEquipmentObjectsCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.159cucsEquipmentBreakoutCapTableCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.159.1cucsEquipmentBreakoutCapEntryCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB
1.3.6.1.4.1.9.9.719.1.15.159.1.9cucsEquipmentBreakoutCapPolicyOwnerCISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB