All MIBs › CISCO-UNIFIED-COMPUTING-DIAG-MIB › cucsDiagRsltTestDn
cucsDiagRsltTestDn
Module: CISCO-UNIFIED-COMPUTING-DIAG-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-DIAG-MIB::cucsDiagRsltTestDn
OID (numeric): 1.3.6.1.4.1.9.9.719.1.12.3.1.12
Node type: OBJECT-TYPE
Type: SnmpAdminString
Access: read-only
Description: Cisco UCS diag:Rslt:testDn managed object property
What is cucsDiagRsltTestDn?
This points back to the Dn of the actual test definition object, such as a memory test, that produced this result. An admin reviewing a failed result uses this cross-reference to jump straight to the test's configuration, such as loop count, pattern, and memory size, to understand exactly what parameters were used when the failure occurred, before deciding whether to rerun with different settings. A value like 'sys/chassis-1/blade-2/diag/memory-test-1' ties this specific failed result back to that exact test configuration.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.12.3.1.12 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-DIAG-MIB::cucsDiagRsltTestDn
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.12.3.1.12.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-DIAG-MIB::cucsDiagRsltTestDn.1
Start monitoring Cisco UCS blade servers (hardware diagnostics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-DIAG-MIB::cucsDiagRsltTestDn OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers (hardware diagnostics) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.12 | cucsDiagObjects | CISCO-UNIFIED-COMPUTING-DIAG-MIB |
| 1.3.6.1.4.1.9.9.719.1.12.3 | cucsDiagRsltTable | CISCO-UNIFIED-COMPUTING-DIAG-MIB |
| 1.3.6.1.4.1.9.9.719.1.12.3.1 | cucsDiagRsltEntry | CISCO-UNIFIED-COMPUTING-DIAG-MIB |
| 1.3.6.1.4.1.9.9.719.1.12.3.1.12 | cucsDiagRsltTestDn | CISCO-UNIFIED-COMPUTING-DIAG-MIB |