CISCO-UNIFIED-COMPUTING-CONFIG-MIB :: cucsConfigManagedEpImpactResponseImpactAnalyzerId

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-UNIFIED-COMPUTING-CONFIG-MIB › cucsConfigManagedEpImpactResponseImpactAnalyzerId

cucsConfigManagedEpImpactResponseImpactAnalyzerId

Module: CISCO-UNIFIED-COMPUTING-CONFIG-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-CONFIG-MIB::cucsConfigManagedEpImpactResponseImpactAnalyzerId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.61.3.1.7

Node type: OBJECT-TYPE

Type: DateAndTime

Access: read-only

Description: Cisco UCS config:ManagedEpImpactResponse:impactAnalyzerId managed object property

What is cucsConfigManagedEpImpactResponseImpactAnalyzerId?

This DateAndTime-typed 'impactAnalyzerId' identifies the specific impact-analysis run this response belongs to (despite the DateAndTime syntax, its role per the MIB naming is as an analysis-run identifier). This ties a per-domain response back to the specific overall impact-analysis request it was generated for, which matters when several analyses are queued for the same proposed change over time. Two responses sharing the same impactAnalyzerId value confirm they were both generated in answer to the same specific impact-analysis request.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.61.3.1.7
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-CONFIG-MIB::cucsConfigManagedEpImpactResponseImpactAnalyzerId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.61.3.1.7.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-CONFIG-MIB::cucsConfigManagedEpImpactResponseImpactAnalyzerId.1

Start monitoring Cisco UCS Manager-managed blade/rack servers and fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-CONFIG-MIB::cucsConfigManagedEpImpactResponseImpactAnalyzerId OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager-managed blade/rack servers and fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.61cucsConfigObjectsCISCO-UNIFIED-COMPUTING-CONFIG-MIB
1.3.6.1.4.1.9.9.719.1.61.3cucsConfigManagedEpImpactResponseTableCISCO-UNIFIED-COMPUTING-CONFIG-MIB
1.3.6.1.4.1.9.9.719.1.61.3.1cucsConfigManagedEpImpactResponseEntryCISCO-UNIFIED-COMPUTING-CONFIG-MIB
1.3.6.1.4.1.9.9.719.1.61.3.1.7cucsConfigManagedEpImpactResponseImpactAnalyzerIdCISCO-UNIFIED-COMPUTING-CONFIG-MIB