CISCO-UNIFIED-COMPUTING-CONFIG-MIB :: cucsConfigImpactAffectedServer

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-UNIFIED-COMPUTING-CONFIG-MIB › cucsConfigImpactAffectedServer

cucsConfigImpactAffectedServer

Module: CISCO-UNIFIED-COMPUTING-CONFIG-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-CONFIG-MIB::cucsConfigImpactAffectedServer

OID (numeric): 1.3.6.1.4.1.9.9.719.1.61.2.1.5

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS config:Impact:affectedServer managed object property

What is cucsConfigImpactAffectedServer?

The 'affectedServer' property lists the specific server or servers the pending configuration change is predicted to disrupt. This is the field an admin actually reads before approving a change, since it names exactly which physical servers (and therefore which running workloads) would be affected. For a template change binding twelve service profiles, affectedServer might list the dns of all twelve associated blades.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.61.2.1.5
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-CONFIG-MIB::cucsConfigImpactAffectedServer

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.61.2.1.5.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-CONFIG-MIB::cucsConfigImpactAffectedServer.1

Start monitoring Cisco UCS Manager-managed blade/rack servers and fabric interconnects with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-CONFIG-MIB::cucsConfigImpactAffectedServer OID value, configure state conditions and alerts, and monitor any Cisco UCS Manager-managed blade/rack servers and fabric interconnects from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.61cucsConfigObjectsCISCO-UNIFIED-COMPUTING-CONFIG-MIB
1.3.6.1.4.1.9.9.719.1.61.2cucsConfigImpactTableCISCO-UNIFIED-COMPUTING-CONFIG-MIB
1.3.6.1.4.1.9.9.719.1.61.2.1cucsConfigImpactEntryCISCO-UNIFIED-COMPUTING-CONFIG-MIB
1.3.6.1.4.1.9.9.719.1.61.2.1.5cucsConfigImpactAffectedServerCISCO-UNIFIED-COMPUTING-CONFIG-MIB