CISCO-UNIFIED-COMPUTING-COMPUTE-MIB :: cucsComputeRackUnitPhysicalSecurity

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-COMPUTE-MIBcucsComputeRackUnitPhysicalSecurity

cucsComputeRackUnitPhysicalSecurity

Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitPhysicalSecurity

OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.35.1.73

Node type: OBJECT-TYPE

Type: CucsEquipmentPhysicalSecurityState

Access: read-only

Description: Cisco UCS compute:RackUnit:physicalSecurity managed object property

What is cucsComputeRackUnitPhysicalSecurity?

This CucsEquipmentPhysicalSecurityState reports whether a physical intrusion or chassis-security event has been detected on this rack server, such as the chassis cover being opened. An admin monitoring for unauthorized physical access to sensitive hardware watches this field specifically as a tamper-detection signal separate from any of the operational health fields. A value of 'chassis-open-fault' would indicate the chassis intrusion sensor detected the cover being opened.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.35.1.73
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitPhysicalSecurity

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.35.1.73.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitPhysicalSecurity.1

Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitPhysicalSecurity OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.9cucsComputeObjectsCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.35cucsComputeRackUnitTableCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.35.1cucsComputeRackUnitEntryCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.35.1.73cucsComputeRackUnitPhysicalSecurityCISCO-UNIFIED-COMPUTING-COMPUTE-MIB