CISCO-UNIFIED-COMPUTING-COMPUTE-MIB :: cucsComputeRackUnitMbTempStatsHistSuspect

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-COMPUTE-MIBcucsComputeRackUnitMbTempStatsHistSuspect

cucsComputeRackUnitMbTempStatsHistSuspect

Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsHistSuspect

OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.45.1.26

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Cisco UCS compute:RackUnitMbTempStatsHist:suspect managed object property

What is cucsComputeRackUnitMbTempStatsHistSuspect?

This TruthValue preserves, for this specific historical record, whether the motherboard temperature readings at that past moment were flagged as unreliable due to a sensor glitch, mirroring the live suspect flag but frozen at that point in time. An admin investigating an apparent past thermal anomaly should check this flag first, since a historical record marked suspect shouldn't be trusted as evidence of a real thermal event. A value of 'true' on a historical record with otherwise odd readings would explain those readings as a sensor glitch rather than a genuine thermal excursion.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.45.1.26
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsHistSuspect

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.45.1.26.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsHistSuspect.1

Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsHistSuspect OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.9cucsComputeObjectsCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.45cucsComputeRackUnitMbTempStatsHistTableCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.45.1cucsComputeRackUnitMbTempStatsHistEntryCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.45.1.26cucsComputeRackUnitMbTempStatsHistSuspectCISCO-UNIFIED-COMPUTING-COMPUTE-MIB