CISCO-UNIFIED-COMPUTING-COMPUTE-MIB :: cucsComputeRackUnitMbTempStatsHistIoh2Temp

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-COMPUTE-MIBcucsComputeRackUnitMbTempStatsHistIoh2Temp

cucsComputeRackUnitMbTempStatsHistIoh2Temp

Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsHistIoh2Temp

OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.45.1.17

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS compute:RackUnitMbTempStatsHist:ioh2Temp managed object property

What is cucsComputeRackUnitMbTempStatsHistIoh2Temp?

This INTEGER preserves the second I/O hub chip's temperature reading captured at the specific past moment this historical record represents, the historical counterpart to the live ioh2Temp field for the board's other IOH chip. An admin comparing this against the same-interval ioh1Temp historical value can determine whether a past thermal event was localized to one side of the board or affected both chips equally. A gap between the two historical IOH readings for the same interval would point to a localized past issue.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.45.1.17
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsHistIoh2Temp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.45.1.17.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsHistIoh2Temp.1

Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsHistIoh2Temp OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.9cucsComputeObjectsCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.45cucsComputeRackUnitMbTempStatsHistTableCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.45.1cucsComputeRackUnitMbTempStatsHistEntryCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.45.1.17cucsComputeRackUnitMbTempStatsHistIoh2TempCISCO-UNIFIED-COMPUTING-COMPUTE-MIB