CISCO-UNIFIED-COMPUTING-COMPUTE-MIB :: cucsComputeRackUnitMbTempStatsFrontTemp

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-COMPUTE-MIBcucsComputeRackUnitMbTempStatsFrontTemp

cucsComputeRackUnitMbTempStatsFrontTemp

Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsFrontTemp

OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.44.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Cisco UCS compute:RackUnitMbTempStats:frontTemp managed object property

What is cucsComputeRackUnitMbTempStatsFrontTemp?

This INTEGER reports the current temperature reading (degrees C) from the sensor positioned at the front of the motherboard, near the intake airflow, distinct from the general ambientTemp reading. An admin troubleshooting a specific hot spot inside the chassis compares frontTemp against rearTemp and the I/O hub readings to localize where inside the server heat is actually building up. A value of 26 would be a typical front-of-board reading in normal operation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.44.1.8
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsFrontTemp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.44.1.8.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsFrontTemp.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cucsComputeRackUnitMbTempStatsFrontTemp.1

Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitMbTempStatsFrontTemp OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.9cucsComputeObjectsCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.44cucsComputeRackUnitMbTempStatsTableCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.44.1cucsComputeRackUnitMbTempStatsEntryCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.44.1.8cucsComputeRackUnitMbTempStatsFrontTempCISCO-UNIFIED-COMPUTING-COMPUTE-MIB