CISCO-UNIFIED-COMPUTING-COMPUTE-MIB :: cucsComputeRackUnitKmipFaultDescription

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-COMPUTE-MIBcucsComputeRackUnitKmipFaultDescription

cucsComputeRackUnitKmipFaultDescription

Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitKmipFaultDescription

OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.35.1.72

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-only

Description: Cisco UCS compute:RackUnit:kmipFaultDescription managed object property

What is cucsComputeRackUnitKmipFaultDescription?

This SnmpAdminString supplies the human-readable description accompanying a KMIP fault flagged by kmipFault, explaining the specific nature of the key-management problem. An admin escalating a self-encrypting-drive access issue quotes this description directly since it typically identifies whether the problem is connectivity to the KMIP server, a certificate issue, or a key-retrieval failure. A typical value would read something like 'Unable to reach the configured KMIP server'.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.35.1.72
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitKmipFaultDescription

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.35.1.72.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitKmipFaultDescription.1

Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitKmipFaultDescription OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.9cucsComputeObjectsCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.35cucsComputeRackUnitTableCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.35.1cucsComputeRackUnitEntryCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.35.1.72cucsComputeRackUnitKmipFaultDescriptionCISCO-UNIFIED-COMPUTING-COMPUTE-MIB