CISCO-UNIFIED-COMPUTING-COMPUTE-MIB :: cucsComputeRackUnitKmipFault

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-COMPUTE-MIBcucsComputeRackUnitKmipFault

cucsComputeRackUnitKmipFault

Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitKmipFault

OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.35.1.71

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Cisco UCS compute:RackUnit:kmipFault managed object property

What is cucsComputeRackUnitKmipFault?

This TruthValue flags whether a KMIP (Key Management Interoperability Protocol) fault is currently active on this rack server, relevant specifically to servers using self-encrypting drives that rely on an external KMIP key server for their encryption keys. An admin sees a value of true here as an urgent signal, since a KMIP fault can mean self-encrypting drives lose access to their unlock keys, potentially blocking the server from properly accessing encrypted storage. A value of 'false' confirms normal, unobstructed key-management connectivity.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.35.1.71
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitKmipFault

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.35.1.71.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitKmipFault.1

Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackUnitKmipFault OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.9cucsComputeObjectsCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.35cucsComputeRackUnitTableCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.35.1cucsComputeRackUnitEntryCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.35.1.71cucsComputeRackUnitKmipFaultCISCO-UNIFIED-COMPUTING-COMPUTE-MIB