CISCO-UNIFIED-COMPUTING-COMPUTE-MIB :: cucsComputeRackQualMaxId

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-COMPUTE-MIBcucsComputeRackQualMaxId

cucsComputeRackQualMaxId

Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackQualMaxId

OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.43.1.4

Node type: OBJECT-TYPE

Type: CucsComputeRackQualMaxId

Access: read-only

Description: Cisco UCS compute:RackQual:maxId managed object property

What is cucsComputeRackQualMaxId?

This reports the upper bound of the rack-unit ID range that this qualifier will match when UCS Manager evaluates which physical rack servers qualify for a server pool. It matters directly because setting this too high or too low silently changes which rack servers get pulled into (or excluded from) an automated server pool used for service-profile assignment. A concrete value of 120 combined with a corresponding minId would match any rack unit with an ID at or below 120.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.43.1.4
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackQualMaxId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.43.1.4.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackQualMaxId.1

Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputeRackQualMaxId OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.9cucsComputeObjectsCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.43cucsComputeRackQualTableCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.43.1cucsComputeRackQualEntryCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.43.1.4cucsComputeRackQualMaxIdCISCO-UNIFIED-COMPUTING-COMPUTE-MIB