All MIBs › CISCO-UNIFIED-COMPUTING-COMPUTE-MIB › cucsComputePhysicalFsmRmtRslt
cucsComputePhysicalFsmRmtRslt
Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePhysicalFsmRmtRslt
OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.50.1.11
Node type: OBJECT-TYPE
Type: CucsConditionRemoteInvRslt
Access: read-only
Description: Cisco UCS compute:PhysicalFsm:rmtRslt managed object property
What is cucsComputePhysicalFsmRmtRslt?
The desc ties this to the rmtRslt property of a UCS PhysicalFsm object. This records the overall result classification of the remote invocation behind the current FSM step (e.g. success, timeout, or a specific failure class), which is what UCS Manager's fault logic actually branches on to decide whether to retry, fail, or move to the next stage. Example: an rmtRslt of a timeout value on a discovery step would cause UCS Manager to retry rather than immediately mark the whole server discovery as failed.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.50.1.11 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePhysicalFsmRmtRslt
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.50.1.11.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePhysicalFsmRmtRslt.1
Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePhysicalFsmRmtRslt OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.9 | cucsComputeObjects | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |
| 1.3.6.1.4.1.9.9.719.1.9.50 | cucsComputePhysicalFsmTable | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |
| 1.3.6.1.4.1.9.9.719.1.9.50.1 | cucsComputePhysicalFsmEntry | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |
| 1.3.6.1.4.1.9.9.719.1.9.50.1.11 | cucsComputePhysicalFsmRmtRslt | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |