CISCO-UNIFIED-COMPUTING-COMPUTE-MIB :: cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksH

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-COMPUTE-MIBcucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksH

cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksH

Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksH

OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.21.1.52

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS compute:PCIeFatalReceiveStats:unsupportedRequestErrors2 WeeksH managed object property

What is cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksH?

This Gauge32 holds the highest single-sample count of PCIe unsupported request errors that UCS Manager observed during any one collection interval within the last 14 days, i.e. the device received a PCIe transaction (e.g. an access to an unimplemented register or capability) that it does not support, captured at its worst moment. Unlike the plain (non-H) gauge for this window, this high-water value stays latched at the worst reading for the rest of the window even if the fault stops recurring, which is what lets an admin catch a brief PCIe error burst that a simple end-of-window snapshot would have missed. For example, if a marginal riser produced a spike of 27 PCIe unsupported request errors in one polling cycle and then went quiet, this field would hold 27 until the last 14 days window rolls forward, even though the plain gauge has since dropped to 0.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.21.1.52
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksH

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.21.1.52.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksH.1

Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksH OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.9cucsComputeObjectsCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.21cucsComputePCIeFatalReceiveStatsTableCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.21.1cucsComputePCIeFatalReceiveStatsEntryCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.21.1.52cucsComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksHCISCO-UNIFIED-COMPUTING-COMPUTE-MIB