All MIBs › CISCO-UNIFIED-COMPUTING-COMPUTE-MIB › cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DayH
cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DayH
Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DayH
OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.21.1.26
Node type: OBJECT-TYPE
Type: Gauge32
Access: read-only
Description: Cisco UCS compute:PCIeFatalReceiveStats:errNonFatalErrors1DayH managed object property
What is cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DayH?
This Gauge32 holds the highest single-sample count of PCIe ERR_NONFATAL messages that UCS Manager observed during any one collection interval within the last day, i.e. the link partner signalled a recoverable (non-fatal) PCIe error condition over the ERR_NONFATAL sideband message, captured at its worst moment. Unlike the plain (non-H) gauge for this window, this high-water value stays latched at the worst reading for the rest of the window even if the fault stops recurring, which is what lets an admin catch a brief PCIe error burst that a simple end-of-window snapshot would have missed. For example, if a marginal riser produced a spike of 11 PCIe ERR_NONFATAL messages in one polling cycle and then went quiet, this field would hold 11 until the last day window rolls forward, even though the plain gauge has since dropped to 0.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.21.1.26 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DayH
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.21.1.26.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DayH.1
Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DayH OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.9 | cucsComputeObjects | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |
| 1.3.6.1.4.1.9.9.719.1.9.21 | cucsComputePCIeFatalReceiveStatsTable | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |
| 1.3.6.1.4.1.9.9.719.1.9.21.1 | cucsComputePCIeFatalReceiveStatsEntry | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |
| 1.3.6.1.4.1.9.9.719.1.9.21.1.26 | cucsComputePCIeFatalReceiveStatsErrNonFatalErrors1DayH | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |