CISCO-UNIFIED-COMPUTING-COMPUTE-MIB :: cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourH

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-UNIFIED-COMPUTING-COMPUTE-MIBcucsComputePCIeFatalReceiveStatsErrFatalErrors1HourH

cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourH

Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourH

OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.21.1.19

Node type: OBJECT-TYPE

Type: Gauge32

Access: read-only

Description: Cisco UCS compute:PCIeFatalReceiveStats:errFatalErrors1HourH managed object property

What is cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourH?

This Gauge32 holds the highest single-sample count of PCIe ERR_FATAL messages that UCS Manager observed during any one collection interval within the last hour, i.e. the link partner signalled an unrecoverable (fatal) PCIe error condition over the ERR_FATAL sideband message, captured at its worst moment. Unlike the plain (non-H) gauge for this window, this high-water value stays latched at the worst reading for the rest of the window even if the fault stops recurring, which is what lets an admin catch a brief PCIe error burst that a simple end-of-window snapshot would have missed. For example, if a marginal riser produced a spike of 7 PCIe ERR_FATAL messages in one polling cycle and then went quiet, this field would hold 7 until the last hour window rolls forward, even though the plain gauge has since dropped to 0.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.21.1.19
snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourH

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.21.1.19.1
snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourH.1

Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourH OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.719ciscoUnifiedComputingMIBCISCO-UNIFIED-COMPUTING-MIB
1.3.6.1.4.1.9.9.719.1ciscoUnifiedComputingMIBObjectsCISCO-UNIFIED-COMPUTING-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.719.1.9cucsComputeObjectsCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.21cucsComputePCIeFatalReceiveStatsTableCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.21.1cucsComputePCIeFatalReceiveStatsEntryCISCO-UNIFIED-COMPUTING-COMPUTE-MIB
1.3.6.1.4.1.9.9.719.1.9.21.1.19cucsComputePCIeFatalReceiveStatsErrFatalErrors1HourHCISCO-UNIFIED-COMPUTING-COMPUTE-MIB