All MIBs › CISCO-UNIFIED-COMPUTING-COMPUTE-MIB › cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksH
cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksH
Module: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksH
OID (numeric): 1.3.6.1.4.1.9.9.719.1.9.19.1.41
Node type: OBJECT-TYPE
Type: Gauge32
Access: read-only
Description: Cisco UCS compute:PCIeFatalCompletionStats:unexpectedErrors2Weeks H managed object property
What is cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksH?
This Gauge32 holds the highest single-sample count of unexpected PCIe completions that UCS Manager observed during any one collection interval within the last 14 days, i.e. the adapter received a completion TLP that did not match any outstanding request it had issued, captured at its worst moment. Unlike the plain (non-H) gauge for this window, this high-water value stays latched at the worst reading for the rest of the window even if the fault stops recurring, which is what lets an admin catch a brief PCIe error burst that a simple end-of-window snapshot would have missed. For example, if a marginal riser produced a spike of 27 unexpected PCIe completions in one polling cycle and then went quiet, this field would hold 27 until the last 14 days window rolls forward, even though the plain gauge has since dropped to 0.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.19.1.41 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksH
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.9.19.1.41.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksH.1
Start monitoring Cisco UCS blade servers and chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-COMPUTE-MIB::cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksH OID value, configure state conditions and alerts, and monitor any Cisco UCS blade servers and chassis from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.9 | cucsComputeObjects | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |
| 1.3.6.1.4.1.9.9.719.1.9.19 | cucsComputePCIeFatalCompletionStatsTable | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |
| 1.3.6.1.4.1.9.9.719.1.9.19.1 | cucsComputePCIeFatalCompletionStatsEntry | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |
| 1.3.6.1.4.1.9.9.719.1.9.19.1.41 | cucsComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksH | CISCO-UNIFIED-COMPUTING-COMPUTE-MIB |