All MIBs › CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB › cucsAdaptorHostFcIfFsmCurrentFsm
cucsAdaptorHostFcIfFsmCurrentFsm
Module: CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB
OID (symbolic): CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB::cucsAdaptorHostFcIfFsmCurrentFsm
OID (numeric): 1.3.6.1.4.1.9.9.719.1.3.112.1.5
Node type: OBJECT-TYPE
Type: CucsAdaptorHostFcIfFsmCurrentFsm
Access: read-only
Description: Cisco UCS adaptor:HostFcIfFsm:currentFsm managed object property
What is cucsAdaptorHostFcIfFsmCurrentFsm?
Reports the name of the currently executing finite state machine (workflow) for a host Fibre Channel interface, such as an activation or configuration process.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.3.112.1.5 snmpwalk -v2c -c public <target> CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB::cucsAdaptorHostFcIfFsmCurrentFsm
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.719.1.3.112.1.5.1 snmpget -v2c -c public <target> CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB::cucsAdaptorHostFcIfFsmCurrentFsm.1
Start monitoring Cisco UCS (Unified Computing System) Manager-managed environments with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB::cucsAdaptorHostFcIfFsmCurrentFsm OID value, configure state conditions and alerts, and monitor any Cisco UCS (Unified Computing System) Manager-managed environments from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| 1.3.6.1.4.1.9.9.719 | ciscoUnifiedComputingMIB | CISCO-UNIFIED-COMPUTING-MIB |
| 1.3.6.1.4.1.9.9.719.1 | ciscoUnifiedComputingMIBObjects | CISCO-UNIFIED-COMPUTING-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.719.1.3 | cucsAdaptorObjects | CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB |
| 1.3.6.1.4.1.9.9.719.1.3.112 | cucsAdaptorHostFcIfFsmTable | CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB |
| 1.3.6.1.4.1.9.9.719.1.3.112.1 | cucsAdaptorHostFcIfFsmEntry | CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB |
| 1.3.6.1.4.1.9.9.719.1.3.112.1.5 | cucsAdaptorHostFcIfFsmCurrentFsm | CISCO-UNIFIED-COMPUTING-ADAPTOR-MIB |