| OID symbolic | OID numeric | Type | Access | Description |
| ciscoTn3270ServerMIB | 1.3.6.1.4.1.9.9.54 | | | The MIB module for TN3270 Server.
MIB description
The PU and LU MIB are defined in RFC 1666. This MIB provides
additional information on IP and LU mapping. The following
entities are managed:
1) TN3270S Global
2) TN3270S Stats on Listen IP/Port basis
3) TN3270S PU
4) TN3270S IP to LU Mapping
5) TN3270S LU to IP Mapping |
| ciscoTn3270ServerMIBCompliance | 1.3.6.1.4.1.9.9.54.3.1.1 | | | The compliance statement for entities which implement
the Cisco Tn3270s MIB |
| ciscoTn3270ServerMIBComplianceObsolete | 1.3.6.1.4.1.9.9.54.3.1.2 | | | The compliance statement for obsolete entities. |
| ciscoTn3270ServerMIBComplianceRev1 | 1.3.6.1.4.1.9.9.54.3.1.3 | | | The compliance statement for the TN3270 Server. |
| ciscoTn3270ServerMIBCompliances | 1.3.6.1.4.1.9.9.54.3.1 | | | |
| ciscoTn3270ServerMIBConformance | 1.3.6.1.4.1.9.9.54.3 | | | |
| ciscoTn3270ServerMIBGroup | 1.3.6.1.4.1.9.9.54.3.2.1 | | | A collection of objects providing Tn3270 ability to a
Cisco agent. |
| ciscoTn3270ServerMIBGroupObsolete | 1.3.6.1.4.1.9.9.54.3.2.2 | | | A collection of objects providing Tn3270 ability to a
Cisco agent. |
| ciscoTn3270ServerMIBGroupRev1 | 1.3.6.1.4.1.9.9.54.3.2.3 | | | A collection of objects providing LU nailing and IP
precedence features. |
| ciscoTn3270ServerMIBGroups | 1.3.6.1.4.1.9.9.54.3.2 | | | |
| ciscoTn3270ServerMIBNotificationPrefix | 1.3.6.1.4.1.9.9.54.2 | | | |
| TN3 tn3270sCpuCard | 1.3.6.1.4.1.9.9.54.1.1.1.1.2 | Tn3270sCpuCard | read-only | The identity of the board running the server. |
| tn3270sGlobal | 1.3.6.1.4.1.9.9.54.1.1 | | | |
| tn3270sGlobalEntry | 1.3.6.1.4.1.9.9.54.1.1.1.1 | | not-accessible | Parameters values for a group. |
| INT tn3270sGlobalGenericPool | 1.3.6.1.4.1.9.9.54.1.1.1.1.10 | INTEGER | read-only | This variable indicates whether or not leftover LUs
will be made available to tn3270 sessions which
do not request a specific LU or LU pool.
A 'leftover' LU is defined as one for which all of the
following conditions hold true:
.the SSCP did not send an ACTLU during PU startup; and
.the PU controlling the LU is capable of carrying PSID
vectors on NMVT messages(thus allowing DDDLU operation
for that LU).
deny indicates that the leftover LUs should not
be given to a generic pool (ie, the PU is not
automatically fully populated with 255 LOCADDR definitions);
permit indicates leftover LUs should be made available to
tn3270 users wanting 'generic' sessions. All LUs in the
generic pool are (by definition) Dynamic Definition of
Dependant (DDDLU) capable. |
| INT tn3270sGlobalIdleTimeout | 1.3.6.1.4.1.9.9.54.1.1.1.1.7 | INTEGER | read-only | The number of seconds of LU inactivity (from either
host or client) before the TN3270 session is disconnected.
Zero seconds means that LU sessions, by default, will
not be disconnected when inactive, regardless of the
amount of idle time spent. |
| INT tn3270sGlobalKeepAlive | 1.3.6.1.4.1.9.9.54.1.1.1.1.8 | INTEGER | read-only | The number of seconds of inactivity from client side
which the TN3270 Server allows to elapse before sending
DO-TIMING-MARK to the TN3270 client. If the client does
not reply within thirty minutes of such a TIMING-MARK
sending, the server disconnects the tn3270 session.
Zero seconds indicates that no keepalives will be sent. |
| tn3270sGlobalTable | 1.3.6.1.4.1.9.9.54.1.1.1 | | not-accessible | A list of TN3270 server and DLUR global information. |
| TN3 tn3270sGlobalTcpPort | 1.3.6.1.4.1.9.9.54.1.1.1.1.6 | Tn3270sTCPPort | read-only | The default TCP port of this TN3270 Server, which is
inherited by the PU if it doesn't have the TCP port
explicitly defined in the router configuration for this PU. |
| INT tn3270sGlobalUnbindAction | 1.3.6.1.4.1.9.9.54.1.1.1.1.9 | INTEGER | read-only | This variable indicates whether or not a tn3270 session
will be disconnected upon UNBIND.
keep indicates that no automatic disconnect will be made
by the server upon receipt of an UNBIND.
disconnect indicates that the session will be
disconnected upon receipt of an UNBIND. |
| TN3 tn3270sIndex | 1.3.6.1.4.1.9.9.54.1.1.1.1.1 | Tn3270sUnsigned32 | not-accessible | Index used to uniquely identify each tn3270 server
instance. This index value shall not be reused when
the server is shut down and a new instance invoked. |
| tn3270sIp | 1.3.6.1.4.1.9.9.54.1.4 | | | |
| IP tn3270sIpClientAddr | 1.3.6.1.4.1.9.9.54.1.4.1.1.1 | IpAddress | not-accessible | The ip address of the TN3270 client. |
| TN3 tn3270sIpClientTcpPort | 1.3.6.1.4.1.9.9.54.1.4.1.1.2 | Tn3270sTCPPort | not-accessible | The TCP port of the TN3270 client. |
| tn3270sIpEntry | 1.3.6.1.4.1.9.9.54.1.4.1.1 | | not-accessible | A list of entries to relate a client IP address to the
LU |
| TN3 tn3270sIpLuIndex | 1.3.6.1.4.1.9.9.54.1.4.1.1.4 | Tn3270sLUIndex | read-only | The LU index associated with NAU and LU objects. |
| tn3270sIpNail | 1.3.6.1.4.1.9.9.54.1.7 | | | |
| IP tn3270sIpNailClientIpAddr | 1.3.6.1.4.1.9.9.54.1.7.1.1.1 | IpAddress | read-only | The IP address of the nailed TN3270 client. |
| IP tn3270sIpNailClientIpMask | 1.3.6.1.4.1.9.9.54.1.7.1.1.2 | IpAddress | read-only | The subnet mask of the nailed TN3270 client. |
| tn3270sIpNailEntry | 1.3.6.1.4.1.9.9.54.1.7.1.1 | | not-accessible | A list of entries to relate a PU to nailed
clients. This table contains the same info as
tn3270sPuNailTable. The indices are ordered to
facilitate access to the info when the client
IP address is known but not the PU index.
This is necessitated due to the potentially large
number of rows in the table. |
| INT tn3270sIpNailLuFirst | 1.3.6.1.4.1.9.9.54.1.7.1.1.4 | INTEGER | read-only | The first LU in this range nailed to this client ip
address. |
| INT tn3270sIpNailLuLast | 1.3.6.1.4.1.9.9.54.1.7.1.1.5 | INTEGER | read-only | The last LU in this range nailed to this client ip
address. |
| tn3270sIpNailTable | 1.3.6.1.4.1.9.9.54.1.7.1 | | not-accessible | A list of reserved LUs and their associated IP
addresses is represented here for the containing
PU. Each LU is configured for a specific client
IP address. This association between the LU and
the client IP Address is called nailing. The client
is said to be nailed to its LU and visa-versa.
If the PU index is known but the client IP address
is not known, a more efficient way to access
this info is via tn3270sPuNailTable. |
| INT tn3270sIpNailType | 1.3.6.1.4.1.9.9.54.1.7.1.1.3 | INTEGER | read-only | The nailing type configured for the range of LUs
within this PU is either screen or printer.
screen - The range of LUs will only be connected to
TN3270 clients with a device type which is
not 328*. If an LU is statically configured
at the host, then it should be configured
with a screen DLOGMOD definition.
printer - The range of LUs will only be connected to
TN3270 clients with device type which is 328*.
If an LU is statically configured at the
host, then it should be configured with
a printer DLOGMOD definition. |
| TN3 tn3270sIpPuIndex | 1.3.6.1.4.1.9.9.54.1.4.1.1.3 | Tn3270sPUIndex | read-only | The PU index associated with NAU and PU objects |
| tn3270sIpTable | 1.3.6.1.4.1.9.9.54.1.4.1 | | not-accessible | A list of IP to LU mapping entries |
| INT tn3270sLocalSapAddress | 1.3.6.1.4.1.9.9.54.1.3.1.1.11 | INTEGER | read-only | SAP address of the local direct node. |
| tn3270sLu | 1.3.6.1.4.1.9.9.54.1.5 | | | |
| STR tn3270sLuAppnLinkIndex | 1.3.6.1.4.1.9.9.54.1.5.1.1.13 | DisplayString | read-only | This is the link index into APPN mib for link on which
bind flowed; only valid for DLUR LU. |
| IP tn3270sLuClientAddr | 1.3.6.1.4.1.9.9.54.1.5.1.1.3 | IpAddress | read-only | The ip address of the TN3270 client connected to this LU. |
| TN3 tn3270sLuClientTcpPort | 1.3.6.1.4.1.9.9.54.1.5.1.1.4 | Tn3270sTCPPort | read-only | The TCP port of the TN3270 client connected to this LU. |
| INT tn3270sLuCurInbPacing | 1.3.6.1.4.1.9.9.54.1.5.1.1.8 | INTEGER | read-only | The number of inbound frames allowed to be sent to the
host without receiving a pacing response from the host. |
| INT tn3270sLuCurInbQsize | 1.3.6.1.4.1.9.9.54.1.5.1.1.9 | INTEGER | read-only | After inbound pacing credit is exhausted, the inbound
data is queued. This is the number of inbound frames
queued waiting for host pacing response. |
| INT tn3270sLuCurOutQsize | 1.3.6.1.4.1.9.9.54.1.5.1.1.10 | INTEGER | read-only | The number of TCP packets in the server queued for
transmission to the client |
| tn3270sLuEntry | 1.3.6.1.4.1.9.9.54.1.5.1.1 | | not-accessible | Parameters values for a group. |
| OCT tn3270sLuEvents | 1.3.6.1.4.1.9.9.54.1.5.1.1.16 | OCTET STRING | read-only | An array of octets indicating the latest events which
happened in this LU. Octet 1 is the most recent event,
octet 2 the next most recent and so on. Although
the maximum number of events kept is 16, the actual
number of events kept may be lower than that. When more
events are generated than are kept, the oldest ones are
discarded.
Events are encoded as:
1 inactivity timer expired.
2 dynamic timer expired,
3 actlu from host
4 bind from host
5 clear from host
6 dactlu from host
7 hierarchical reset from PU (warn actpu)
8 sdt from host
9 unbind from host
10 notify response from host
11 Reply psid negative response from host
12 Reply psid pos response from host
13 unbind response from host
14 hierarchical reset from pu
15 connect from client
16 disconnect from client
17 timing-mark response from client
18 flow control timer expired
19 negative response to host
20 negative response from host
21 data contention happened
22 no buffer to send response
23 receive a sna response while inbound |
| INT tn3270sLuIdleTime | 1.3.6.1.4.1.9.9.54.1.5.1.1.11 | INTEGER | read-only | Time since last activity was recorded on this LU. |
| TN3 tn3270sLuIndex | 1.3.6.1.4.1.9.9.54.1.5.1.1.2 | Tn3270sLUIndex | not-accessible | Index used to uniquely identify the LU instance within
a PU. It is the locaddr. This is the same as
snaLuAdminLuIndex in the NAU MIB. |
| TIM tn3270sLuLastEvent | 1.3.6.1.4.1.9.9.54.1.5.1.1.15 | TimeStamp | read-only | Time at which the last data was logged for this LU. |
| INT tn3270sLuLfsid | 1.3.6.1.4.1.9.9.54.1.5.1.1.14 | INTEGER | read-only | This is the session identifier on a PU 2.1 link. |
| T/F tn3270sLuNail | 1.3.6.1.4.1.9.9.54.1.5.1.1.17 | TruthValue | read-only | This variable indicates whether this LU has been
configured (Nailed) for a specific TN3270 client.
TRUE -> LU is nailed to the client IP address
FALSE -> LU is not nailed to the client IP address |
| TN3 tn3270sLuPuIndex | 1.3.6.1.4.1.9.9.54.1.5.1.1.1 | Tn3270sPUIndex | not-accessible | Index used to uniquely identify each PU instance. This
is the same as snaNodeAdminIndex in the NAU MIB. |
| G32 tn3270sLusInUse | 1.3.6.1.4.1.9.9.54.1.1.1.1.4 | Gauge32 | read-only | The number of LUs currently in use on the server. |
| INT tn3270sLuState | 1.3.6.1.4.1.9.9.54.1.5.1.1.7 | INTEGER | read-only | The value identifies the current LU state.
inactive (1) - LU didn't receive ACTLU.
active (2) - LU received ACTLU and acknowledged
positively.
pSdt (3) - LU is bound but there is no SDT yet.
act/session (4) - LU is bound and in session.
pActlu (5) - telnet connects in and is awating for
ACTLU.
pNotifyAv (6) - awaiting host notify-available response.
pNotifyUa (7) - awaiting host notify-unavailable response.
pReset (8) - awaiting for a buffer to send DACTLU
response.
pPsid (9) - awaiting for NMVT Reply psid response.
pBind (10) - awaiting for host to send bind.
pUnbind (11) - awaiting host unbind response.
unbindWt (12) - awaiting for client to acknowledge
disconnection.
sdtWt (13) - awaiting for client to acknowledge SDT |
| tn3270sLuTable | 1.3.6.1.4.1.9.9.54.1.5.1 | | not-accessible | This helps map LU to client ip/port. Also it provides
other useful parameters not available elsewhere. |
| INT tn3270sLuTelnetType | 1.3.6.1.4.1.9.9.54.1.5.1.1.5 | INTEGER | read-only | This indicates whether the negotiated TN3270 session.
TN3270, TN3270E or never connected. |
| STR tn3270sLuTermModel | 1.3.6.1.4.1.9.9.54.1.5.1.1.6 | DisplayString | read-only | Terminal type or model number of the incoming TN3270 client. |
| INT tn3270sLuType | 1.3.6.1.4.1.9.9.54.1.5.1.1.12 | INTEGER | read-only | This indicates whether LU is dynamic or static.
dynamic (1) - LU is configured as DDDLU.
static (2) - LU is configured as specific. Host will send
ACTLU as soon as PU is active. |
| TN3 tn3270sMaxLus | 1.3.6.1.4.1.9.9.54.1.1.1.1.3 | Tn3270sUnsigned32 | read-only | The maximum number of LUs supported by the server. |
| tn3270sObjects | 1.3.6.1.4.1.9.9.54.1 | | | |
| tn3270sPu | 1.3.6.1.4.1.9.9.54.1.3 | | | |
| tn3270sPuEntry | 1.3.6.1.4.1.9.9.54.1.3.1.1 | | not-accessible | A list of TN3270 server PU parameters |
| INT tn3270sPuGenericPool | 1.3.6.1.4.1.9.9.54.1.3.1.1.7 | INTEGER | read-only | This variable indicates whether or not leftover LUs
will be made available to tn3270 sessions which
do not request a specific LU or LU pool.
A 'leftover' LU is defined as one for which all of
the following conditions hold true:
.the SSCP did not send an ACTLU during PU startup; and
.the PU controlling the LU is capable of carrying PSID
vectors on NMVT messages (thus allowing DDDLU
operation for that LU).
inherit indicates that the value of tn3270sPuGenericPool is
to be the same as tn3270sGlobalGenericPool.
deny indicates that the leftover LUs should not be given
to a generic pool (ie, the PU is not automatically
fully populated with 255 LOCADDR definitions);
permit indicates leftover LUs should be made available to
tn3270 users wanting 'generic' sessions. All LUs in the
generic pool are (by definition) DDDLU capable. |
| INT tn3270sPuIdleTimeout | 1.3.6.1.4.1.9.9.54.1.3.1.1.4 | INTEGER | read-only | The number of seconds of LU inactivity (from either
host or client) before the TN3270 session is
disconnected. Zero seconds means that LU sessions,
by default, will not be disconnected when inactive,
regardless of the amount of idle time spent.
65535 (not valid in server context) indicates that
the idletime value should be taken from the server
context. |
| TN3 tn3270sPuIndex | 1.3.6.1.4.1.9.9.54.1.3.1.1.1 | Tn3270sPUIndex | not-accessible | Index used to uniquely identify each Node instance. This
is the same as snaNodeAdminIndex in the NAU MIB. |
| IP tn3270sPuIpAddr | 1.3.6.1.4.1.9.9.54.1.3.1.1.2 | IpAddress | read-only | The ip address of this TN3270 server. |
| INT tn3270sPuIpPrecedencePrinter | 1.3.6.1.4.1.9.9.54.1.3.1.1.15 | INTEGER | read-only | The value of the PRECEDENCE field in the Type of
Service octet in the IP header set by the TN3270
server for outbound IP packets destined to the TN3270
client printer. That is from the router to the TN3270
client printer. |
| INT tn3270sPuIpPrecedenceScreen | 1.3.6.1.4.1.9.9.54.1.3.1.1.14 | INTEGER | read-only | The value of the PRECEDENCE field in the Type of
Service octet in the IP header set by the TN3270
server for outbound IP packets destined to the TN3270
client screen. That is from the router to the TN3270
client screen. |
| INT tn3270sPuIpTosPrinter | 1.3.6.1.4.1.9.9.54.1.3.1.1.17 | INTEGER | read-only | The value of the TOS field in the Type of Service
octet in the IP header set by the TN3270 server
for outbound IP packets destined to the TN3270
client printer. That is from the router to the TN3270
client printer. |
| INT tn3270sPuIpTosScreen | 1.3.6.1.4.1.9.9.54.1.3.1.1.16 | INTEGER | read-only | The value of the TOS field in the Type of Service
octet in the IP header set by the TN3270 server
for outbound IP packets destined to the TN3270
client screen. That is from the router to the TN3270
client screen. |
| INT tn3270sPuKeepAlive | 1.3.6.1.4.1.9.9.54.1.3.1.1.5 | INTEGER | read-only | The number of seconds of inactivity from client side
which the TN3270 Server allows to elapse before
sending DO-TIMING-MARK to the TN3270 client. If the
client does not reply within thirty minutes of such
a TIMING-MARK sending, the server disconnect the tn3270
session. Zero seconds indicates that no keepalives
will be sent.
65535 (not valid in server context) indicates that the
default keepalive value for an LU is taken from whatever
value had been defined in the server context for this
CIP card. |
| STR tn3270sPuLuSeed | 1.3.6.1.4.1.9.9.54.1.3.1.1.10 | DisplayString | read-only | For Direct PU this defines the LU name prefix (LU seed)
which is concatinated with the locaddr to form a unique
name. |
| tn3270sPuNail | 1.3.6.1.4.1.9.9.54.1.6 | | | |
| IP tn3270sPuNailClientIpAddr | 1.3.6.1.4.1.9.9.54.1.6.1.1.1 | IpAddress | read-only | The IP address of the nailed TN3270 client. |
| IP tn3270sPuNailClientIpMask | 1.3.6.1.4.1.9.9.54.1.6.1.1.2 | IpAddress | read-only | The subnet mask of the nailed TN3270 client. |
| tn3270sPuNailEntry | 1.3.6.1.4.1.9.9.54.1.6.1.1 | | not-accessible | A list of entries to relate a PU to nailed
clients.This table contains the same info as
tn3270sIpNailTable. The indices are ordered to
facilitate access to the information when the
PU index is known but not the client IP address.
This is necessitated due to the potentially large
number of rows in the table. |
| INT tn3270sPuNailLuFirst | 1.3.6.1.4.1.9.9.54.1.6.1.1.4 | INTEGER | read-only | The first LU in this range nailed to this client ip
address. |
| INT tn3270sPuNailLuLast | 1.3.6.1.4.1.9.9.54.1.6.1.1.5 | INTEGER | read-only | The last LU in this range nailed to this client ip
address. |
| tn3270sPuNailTable | 1.3.6.1.4.1.9.9.54.1.6.1 | | not-accessible | A list of reserved LUs and their associated IP
addresses is represented here for the containing
PU. Each LU is configured for a specific client
IP address. This association between the LU and
the client IP Address is called nailing. The client
is said to be nailed to its LU and visa-versa.
If the client IP address is known but the PU index
is not known, a more efficient way to access
this info is via tn3270sIpNailTable. |
| INT tn3270sPuNailType | 1.3.6.1.4.1.9.9.54.1.6.1.1.3 | INTEGER | read-only | The nailing type configured for the range of LUs
within this PU is either screen or printer.
screen - The range of LUs will only be connected to
TN3270 clients with a device type which is
not 328*. If an LU is statically configured
at the host, then it should be configured
with a screen DLOGMOD definition.
printer - The range of LUs will only be connected to
TN3270
clients with device type which is 328*.
If an LU is statically configured at the
host, then it should be configured with
a printer DLOGMOD definition. |
| INT tn3270sPuState | 1.3.6.1.4.1.9.9.54.1.3.1.1.8 | INTEGER | read-only | The value identifies the current PU state. This has
a different meaning for direct or DLUR PU before the
link station is established.
For DLUR PU, the PU is in reset state, for direct PU,
this will be either sending a TEST or XID
shut (1) - The PU is configured but in shut state
reset (2) - The link station of this PU is not active.
inactive (3) - The PU is not activated and the link-station
or DLUR state is unknown.
test (4) - PU is sending a TEST to establish link.
xid (5) - TEST is responded, XID is sent.
pActpu (6) - The link station is up but no ACTPU is
received.
active (7) - ACTPU is received and acknowledged positively.
actBusy (8) - Awaiting host to acknowledge the SSCP-PU data. |
| tn3270sPuTable | 1.3.6.1.4.1.9.9.54.1.3.1 | | not-accessible | This table contains objects which describe the PU
configuration parameters not defined in the
NAU mib, APPN mib or DLUR mib |
| TN3 tn3270sPuTcpPort | 1.3.6.1.4.1.9.9.54.1.3.1.1.3 | Tn3270sTCPPort | read-only | The TCP port of this TN3270 server telnet session. |
| INT tn3270sPuType | 1.3.6.1.4.1.9.9.54.1.3.1.1.9 | INTEGER | read-only | This defines whether the connection to the host is
via DLUR or direct link. If DLUR, LuSeed, lmac/sap,
and rmac/sap in this table are undefined. |
| INT tn3270sPuUnbindAction | 1.3.6.1.4.1.9.9.54.1.3.1.1.6 | INTEGER | read-only | This variable indicates whether or not a tn3270 session
will be disconnected upon UNBIND.
keep indicates that no automatic disconnect will be made by
the server upon receipt of an UNBIND.
disconnect indicates that the session will be
disconnected upon receipt of an UNBIND.
inherit indicates that the default keepalive value of an
LU is taken from whatever value had been defined in
the server context for this CIP card. |
| MAC tn3270sRemoteMacAddress | 1.3.6.1.4.1.9.9.54.1.3.1.1.13 | MacAddress | read-only | MAC address of the remote node; valid for direct PU only. |
| INT tn3270sRemoteSapAddress | 1.3.6.1.4.1.9.9.54.1.3.1.1.12 | INTEGER | read-only | SAP address of the remote node; valid for direct PU only. |
| TN3 tn3270sRunningTime | 1.3.6.1.4.1.9.9.54.1.1.1.1.12 | Tn3270sUnsigned32 | read-only | Total time elapsed since start of tn3270 server. |
| TIM tn3270sStartupTime | 1.3.6.1.4.1.9.9.54.1.1.1.1.5 | TimeStamp | read-only | The timestamp when the tn3270 server started. |
| tn3270sStats | 1.3.6.1.4.1.9.9.54.1.2 | | | |
| C32 tn3270sStatsConnectsInEx | 1.3.6.1.4.1.9.9.54.1.2.1.1.5 | Counter32 | read-only | Total number of TN3270 session connects-in received. |
| C32 tn3270sStatsDisconnects | 1.3.6.1.4.1.9.9.54.1.2.1.1.6 | Counter32 | read-only | Total number of TN3270 sessions disconnected. |
| tn3270sStatsEntry | 1.3.6.1.4.1.9.9.54.1.2.1.1 | | not-accessible | The entry contains parameters which describe the
statistics of the ip stacks. |
| C32 tn3270sStatsInboundChains | 1.3.6.1.4.1.9.9.54.1.2.1.1.8 | Counter32 | read-only | Total number of inbound(from client to host) RU chains
(identified by end of record (EOR)) processed. Since
every inbound RU chain is accompanied by client giving
host the direction(CD), it is also a count of number of
client transactions. |
| G32 tn3270sStatsMaxSess | 1.3.6.1.4.1.9.9.54.1.2.1.1.3 | Gauge32 | read-only | Number of Tn3270 sessions configured which are
available to be used by tn3270 clients. |
| TN3 tn3270sStatsNetSampledClientResponseTime | 1.3.6.1.4.1.9.9.54.1.2.1.1.13 | Tn3270sUnsigned32 | read-only | Total response time for all sampled timing marks
on which response time is computed. Response time
is the time diference between sending the timeing mark
to the client and receiving the response from the client.
Note that this is only valid if timeing mark is
configured. Note that the average outbound response
time is given by this object divided by
tn3270sStatsSampledClientResponses. |
| TN3 tn3270sStatsNetSampledHostResponseTime | 1.3.6.1.4.1.9.9.54.1.2.1.1.11 | Tn3270sUnsigned32 | read-only | Total response time for all sampled inbound
transactions for which response time is computed.
Response time is the time difference between receiving
EOR from the client, and receiving the response from the
host. Note that the average response time is given by
this object divided by tn3270sStatsSampledHostResponses. |
| C32 tn3270sStatsOutboundChains | 1.3.6.1.4.1.9.9.54.1.2.1.1.9 | Counter32 | read-only | Total number of Outbound(from host to client) RU Chains
(identified by EOR) processed. |
| C32 tn3270sStatsSampledClientResponses | 1.3.6.1.4.1.9.9.54.1.2.1.1.12 | Counter32 | read-only | Total number of sampled outbound timing marks on
which response time computed. |
| C32 tn3270sStatsSampledHostResponses | 1.3.6.1.4.1.9.9.54.1.2.1.1.10 | Counter32 | read-only | Total number of Sampled Inbound Transactions
(identified by EOR) on which response time is
computed since restart of last listen on
ServerAddress/TcpPort. Counters get reset at
that point. |
| IP tn3270sStatsServerAddr | 1.3.6.1.4.1.9.9.54.1.2.1.1.1 | IpAddress | not-accessible | The ip address of this TN3270 Server Listen endpoint. |
| TN3 tn3270sStatsServerTcpPort | 1.3.6.1.4.1.9.9.54.1.2.1.1.2 | Tn3270sTCPPort | not-accessible | The TCP port in this TN3270 Server Listen endpoint. |
| G32 tn3270sStatsSpareSess | 1.3.6.1.4.1.9.9.54.1.2.1.1.4 | Gauge32 | read-only | Spare number of TN3270 sessions available for connect
at query time. |
| tn3270sStatsTable | 1.3.6.1.4.1.9.9.54.1.2.1 | | not-accessible | A list of statistics for each TN3270 Server Listening
IP/Port pair. |
| C32 tn3270sStatsTN3270ConnectsFailed | 1.3.6.1.4.1.9.9.54.1.2.1.1.7 | Counter32 | read-only | Total number of attempted sessions which failed to
negotiate TN3270/E or were rejected by control point. |
| T/F tn3270sTimingMarkSupported | 1.3.6.1.4.1.9.9.54.1.1.1.1.11 | TruthValue | read-only | This variable indicates whether to send a timing mark to
solicit a response before sending a response to the host.
true indicates that a timing mark is sent, false
indicates that it is not sent.
By using timing mark, an application can determine the
response time from the client. Some existing clients do
not implement the timing mark correctly and will not work
with this server if this parameter is set to true |