CISCO-STACKWISE-MIB :: cswStackPowerMode

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-STACKWISE-MIB › cswStackPowerMode

cswStackPowerMode

Module: CISCO-STACKWISE-MIB

OID (symbolic): CISCO-STACKWISE-MIB::cswStackPowerMode

OID (numeric): 1.3.6.1.4.1.9.9.500.1.3.1.1.2

Node type: OBJECT-TYPE

Type: CswPowerStackMode

Access: read-write

Description: This object specifies the information about the mode of the power stack. Power-sharing mode: All of the input power can be used for loads, and the total available power appears as one huge power supply. The power budget includes all power from all supplies. No power is set aside for power supply failures, so if a power supply fails, load shedding (shutting down of powered devices or switches) might occur. This is the default. Redundant mode: The largest power supply is removed from the power pool to be used as backup power in case one of the other power supplies fails. The available power budget is the total power minus the largest power supply. This reduces the available power in the pool for switches and powered devices to draw from, but in case of a failure or an extreme power load, there is less chance of having to shut down switches or powered devices. This is the recommended operating mode if your system has enough power. In addition, you can configure each mode to run a strict power budget or a non-strict (loose) power budget. If the mode is strict, the stack power needs cannot exceed the available power. When the power budgeted to devices reaches the maximum available PoE power, power is denied to the next device seeking power. In this mode the stack never goes into an over-budgeted power mode. When the mode is non-strict, budgeted power is allowed to exceed available power. This is normally not a problem because most devices do not run at full power and the chances of all powered devices in the stack requiring maximum power at the same time is small.

What is cswStackPowerMode?

Read-write setting describing how the stack power system operates, such as power-sharing mode where all supplies' power is pooled into one shared budget for connected loads.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.500.1.3.1.1.2
snmpwalk -v2c -c public <target> CISCO-STACKWISE-MIB::cswStackPowerMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.500.1.3.1.1.2.1
snmpget -v2c -c public <target> CISCO-STACKWISE-MIB::cswStackPowerMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9.9.500.1.3.1.1.2.1 s <value>

Start monitoring Cisco Catalyst StackWise-capable switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-STACKWISE-MIB::cswStackPowerMode OID value, configure state conditions and alerts, and monitor any Cisco Catalyst StackWise-capable switches from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.500ciscoStackWiseMIBCISCO-STACKWISE-MIB
1.3.6.1.4.1.9.9.500.1ciscoStackWiseMIBObjectsCISCO-STACKWISE-MIB
1.3.6.1.4.1.9.9.500.1.3cswStackPowerInfoCISCO-STACKWISE-MIB
1.3.6.1.4.1.9.9.500.1.3.1cswStackPowerInfoTableCISCO-STACKWISE-MIB
1.3.6.1.4.1.9.9.500.1.3.1.1cswStackPowerInfoEntryCISCO-STACKWISE-MIB
1.3.6.1.4.1.9.9.500.1.3.1.1.2cswStackPowerModeCISCO-STACKWISE-MIB