CISCO-NETSYNC-MIB :: cnsSelInpSrcMSW

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-NETSYNC-MIBcnsSelInpSrcMSW

cnsSelInpSrcMSW

Module: CISCO-NETSYNC-MIB

OID (symbolic): CISCO-NETSYNC-MIB::cnsSelInpSrcMSW

OID (numeric): 1.3.6.1.4.1.9.9.761.1.1.2.1.8

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: This object indicates the manual switching flag. The 'true' value indicates the currently selected clock source is a result of the manual switch command. The command allows a user to select a synchronization source assuming it is enabled, not locked out, not in signal fail condition, and has a QL better than DNU in QL-enabled mode. Furthermore, in QL-enabled mode, a manual switch can be performed only to a source which has the highest available QL.

What is cnsSelInpSrcMSW?

This object indicates whether the currently-selected T0 clock source resulted from a manual switch command rather than fully automatic selection, a softer intervention than a forced switch, since per the description a manual switch can only be issued to a source that is enabled, not locked out, not failed, and, in QL-enabled mode, among those with the best available quality level. It matters because it tells an admin the current source was deliberately chosen by an operator working within the normal quality constraints, as opposed to either fully automatic selection or an override that ignores quality entirely. Distinguishing a true here, a constrained manual choice, from cnsSelInpSrcFSW being true, an unconstrained forced override, tells the admin how much operator discretion, versus emergency override, is behind the current clock selection.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.761.1.1.2.1.8
snmpwalk -v2c -c public <target> CISCO-NETSYNC-MIB::cnsSelInpSrcMSW

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.761.1.1.2.1.8.1
snmpget -v2c -c public <target> CISCO-NETSYNC-MIB::cnsSelInpSrcMSW.1

Start monitoring Cisco routers/switches with SyncE (G.781) clock synchronization with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-NETSYNC-MIB::cnsSelInpSrcMSW OID value, configure state conditions and alerts, and monitor any Cisco routers/switches with SyncE (G.781) clock synchronization from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.761ciscoNetsyncMIBCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1ciscoNetsyncMIBObjectsCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1ciscoNetsyncMIBTablesCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1.2cnsSelectedInputSourceTableCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1.2.1cnsSelectedInputSourceEntryCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1.2.1.8cnsSelInpSrcMSWCISCO-NETSYNC-MIB