CISCO-NETSYNC-MIB :: cnsInpSrcAlarm

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-NETSYNC-MIBcnsInpSrcAlarm

cnsInpSrcAlarm

Module: CISCO-NETSYNC-MIB

OID (symbolic): CISCO-NETSYNC-MIB::cnsInpSrcAlarm

OID (numeric): 1.3.6.1.4.1.9.9.761.1.1.3.1.16

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: This object indicates whether or not an alarm event is currently being reported on the input clock source.

What is cnsInpSrcAlarm?

This object indicates whether an alarm condition, a broader category than just signal failure and potentially including things like frequency-out-of-range or loss-of-signal alarms specific to the interface type, is currently active on this input clock source. It matters as a general-purpose fault flag that an admin polls alongside cnsInpSrcSignalFailure to get a fuller picture of a source's health, since some alarm conditions might be flagged here without necessarily triggering the more specific signal-failure indicator. Seeing this go true on a source that still shows false for signal failure suggests a milder, alarm-only condition rather than a total loss of the timing signal.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.761.1.1.3.1.16
snmpwalk -v2c -c public <target> CISCO-NETSYNC-MIB::cnsInpSrcAlarm

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.761.1.1.3.1.16.1
snmpget -v2c -c public <target> CISCO-NETSYNC-MIB::cnsInpSrcAlarm.1

Start monitoring Cisco routers/switches with SyncE (G.781) clock synchronization with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-NETSYNC-MIB::cnsInpSrcAlarm OID value, configure state conditions and alerts, and monitor any Cisco routers/switches with SyncE (G.781) clock synchronization from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.761ciscoNetsyncMIBCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1ciscoNetsyncMIBObjectsCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1ciscoNetsyncMIBTablesCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1.3cnsInputSourceTableCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1.3.1cnsInputSourceEntryCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1.3.1.16cnsInpSrcAlarmCISCO-NETSYNC-MIB