All MIBs › CISCO-NETSYNC-MIB › cnsExtOutMSW
cnsExtOutMSW
Module: CISCO-NETSYNC-MIB
OID (symbolic): CISCO-NETSYNC-MIB::cnsExtOutMSW
OID (numeric): 1.3.6.1.4.1.9.9.761.1.1.4.1.8
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-only
Description: This object indicates the manual switching flag.
The 'true' value indicates the currently selected T4 clock source is a result of the manual switch command. The command allows a user to select a synchronization source assuming it is enabled, not locked out, not in signal fail condition, and has a QL better than DNU in QL-enabled mode.
A clock source is enabled when it occupies in row in cnsT4ClockSourceTable. A clock source is not locked out when cnsT4ClkSrcLockout contains the value 'false'. A clock source is not in signal failure condition when cnsT4ClkSrcSignalFailure contains the value 'false'. The QL is identified in cnsT4ClkSrcQualityLevel.
In QL-enabled mode, a manual switch can be performed only to a source which has the highest available QL.
What is cnsExtOutMSW?
This object indicates whether the source currently feeding a T4 external output resulted from a manual switch command issued within normal quality and availability constraints, the T4-output analog of cnsInpSrcMSW for T0 sources. It matters for the same auditing reason as its T0 counterpart, distinguishing a deliberate, constrained operator choice from either fully automatic selection or an unconstrained forced override when explaining what is currently being distributed downstream. An admin verifying that a recent maintenance action to manually switch the T4 output to the backup source actually took hold would check this reads true on the expected row.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.761.1.1.4.1.8 snmpwalk -v2c -c public <target> CISCO-NETSYNC-MIB::cnsExtOutMSW
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.761.1.1.4.1.8.1 snmpget -v2c -c public <target> CISCO-NETSYNC-MIB::cnsExtOutMSW.1
Start monitoring Cisco routers/switches with SyncE (G.781) clock synchronization with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-NETSYNC-MIB::cnsExtOutMSW OID value, configure state conditions and alerts, and monitor any Cisco routers/switches with SyncE (G.781) clock synchronization from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.761 | ciscoNetsyncMIB | CISCO-NETSYNC-MIB |
| 1.3.6.1.4.1.9.9.761.1 | ciscoNetsyncMIBObjects | CISCO-NETSYNC-MIB |
| 1.3.6.1.4.1.9.9.761.1.1 | ciscoNetsyncMIBTables | CISCO-NETSYNC-MIB |
| 1.3.6.1.4.1.9.9.761.1.1.4 | cnsExtOutputTable | CISCO-NETSYNC-MIB |
| 1.3.6.1.4.1.9.9.761.1.1.4.1 | cnsExtOutputEntry | CISCO-NETSYNC-MIB |
| 1.3.6.1.4.1.9.9.761.1.1.4.1.8 | cnsExtOutMSW | CISCO-NETSYNC-MIB |