CISCO-NETSYNC-MIB :: cnsExtOutMSW

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-NETSYNC-MIBcnsExtOutMSW

cnsExtOutMSW

Module: CISCO-NETSYNC-MIB

OID (symbolic): CISCO-NETSYNC-MIB::cnsExtOutMSW

OID (numeric): 1.3.6.1.4.1.9.9.761.1.1.4.1.8

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: This object indicates the manual switching flag.

The 'true' value indicates the currently selected T4 clock source is a result of the manual switch command. The command allows a user to select a synchronization source assuming it is enabled, not locked out, not in signal fail condition, and has a QL better than DNU in QL-enabled mode.

A clock source is enabled when it occupies in row in cnsT4ClockSourceTable. A clock source is not locked out when cnsT4ClkSrcLockout contains the value 'false'. A clock source is not in signal failure condition when cnsT4ClkSrcSignalFailure contains the value 'false'. The QL is identified in cnsT4ClkSrcQualityLevel.

In QL-enabled mode, a manual switch can be performed only to a source which has the highest available QL.

What is cnsExtOutMSW?

This object indicates whether the source currently feeding a T4 external output resulted from a manual switch command issued within normal quality and availability constraints, the T4-output analog of cnsInpSrcMSW for T0 sources. It matters for the same auditing reason as its T0 counterpart, distinguishing a deliberate, constrained operator choice from either fully automatic selection or an unconstrained forced override when explaining what is currently being distributed downstream. An admin verifying that a recent maintenance action to manually switch the T4 output to the backup source actually took hold would check this reads true on the expected row.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.761.1.1.4.1.8
snmpwalk -v2c -c public <target> CISCO-NETSYNC-MIB::cnsExtOutMSW

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.761.1.1.4.1.8.1
snmpget -v2c -c public <target> CISCO-NETSYNC-MIB::cnsExtOutMSW.1

Start monitoring Cisco routers/switches with SyncE (G.781) clock synchronization with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-NETSYNC-MIB::cnsExtOutMSW OID value, configure state conditions and alerts, and monitor any Cisco routers/switches with SyncE (G.781) clock synchronization from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.761ciscoNetsyncMIBCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1ciscoNetsyncMIBObjectsCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1ciscoNetsyncMIBTablesCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1.4cnsExtOutputTableCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1.4.1cnsExtOutputEntryCISCO-NETSYNC-MIB
1.3.6.1.4.1.9.9.761.1.1.4.1.8cnsExtOutMSWCISCO-NETSYNC-MIB