CISCO-MGX82XX-DSX3-MIB :: dsx3LCVCurrent

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-MGX82XX-DSX3-MIBdsx3LCVCurrent

dsx3LCVCurrent

Module: CISCO-MGX82XX-DSX3-MIB

OID (symbolic): CISCO-MGX82XX-DSX3-MIB::dsx3LCVCurrent

OID (numeric): 1.3.6.1.4.1.351.110.4.4.1.3.1.1.3

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of Line Code Violations(LCV) encountered by the interface in current 15 minute period.

What is dsx3LCVCurrent?

Reports the number of Line Code Violations (LCV) counted on the interface so far in the current 15-minute interval.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.351.110.4.4.1.3.1.1.3
snmpwalk -v2c -c public <target> CISCO-MGX82XX-DSX3-MIB::dsx3LCVCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.351.110.4.4.1.3.1.1.3.1
snmpget -v2c -c public <target> CISCO-MGX82XX-DSX3-MIB::dsx3LCVCurrent.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> dsx3LCVCurrent.1

Start monitoring Cisco MGX 8200 WAN switch (T3/E3 service modules, legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-MGX82XX-DSX3-MIB::dsx3LCVCurrent OID value, configure state conditions and alerts, and monitor any Cisco MGX 8200 WAN switch (T3/E3 service modules, legacy) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco MGX 8200 WAN switch (T3/E3 service modules, legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type dsx3LCVCurrent into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of Line Code Violations(LCV) encountered by the interface in current 15 minute period. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.351stratacomCISCOWAN-SMI
1.3.6.1.4.1.351.110basisBASIS-MIB
1.3.6.1.4.1.351.110.4basisLinesBASIS-MIB
1.3.6.1.4.1.351.110.4.4dsx3BASIS-MIB
1.3.6.1.4.1.351.110.4.4.1dsx3LineBASIS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.351.110.4.4.1.3dsx3AlarmCISCO-MGX82XX-DSX3-MIB
1.3.6.1.4.1.351.110.4.4.1.3.1dsx3AlarmTableCISCO-MGX82XX-DSX3-MIB
1.3.6.1.4.1.351.110.4.4.1.3.1.1dsx3AlarmEntryCISCO-MGX82XX-DSX3-MIB
1.3.6.1.4.1.351.110.4.4.1.3.1.1.3dsx3LCVCurrentCISCO-MGX82XX-DSX3-MIB