CISCO-LWAPP-CCX-RM-MIB :: clcrClientRxPowerSignal

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CISCO-LWAPP-CCX-RM-MIB › clcrClientRxPowerSignal

clcrClientRxPowerSignal

Module: CISCO-LWAPP-CCX-RM-MIB

OID (symbolic): CISCO-LWAPP-CCX-RM-MIB::clcrClientRxPowerSignal

OID (numeric): 1.3.6.1.4.1.9.9.520.1.4.1.1.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: This object represents the signal strength of the beacon or probe response frame as seen by the client.

What is clcrClientRxPowerSignal?

Read-only value reporting the signal strength of a beacon or probe response frame as measured/reported by a wireless client.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.520.1.4.1.1.2
snmpwalk -v2c -c public <target> CISCO-LWAPP-CCX-RM-MIB::clcrClientRxPowerSignal

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.520.1.4.1.1.2.1
snmpget -v2c -c public <target> CISCO-LWAPP-CCX-RM-MIB::clcrClientRxPowerSignal.1

Start monitoring Cisco Wireless LAN Controller / Lightweight Access Point (CCX) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-LWAPP-CCX-RM-MIB::clcrClientRxPowerSignal OID value, configure state conditions and alerts, and monitor any Cisco Wireless LAN Controller / Lightweight Access Point (CCX) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco Wireless LAN Controller / Lightweight Access Point (CCX) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type clcrClientRxPowerSignal into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This object represents the signal strength of the beacon or probe response frame as seen by the client. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reading drifts outside the range expected for a healthy link (in dBm), since a sustained power drop often precedes a fiber/cable fault or connector issue. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.520ciscoLwappCcxRmMIBCISCO-LWAPP-CCX-RM-MIB
1.3.6.1.4.1.9.9.520.1ciscoLwappCcxRmMIBObjectsCISCO-LWAPP-CCX-RM-MIB
1.3.6.1.4.1.9.9.520.1.4clcrClientMeasurementReportCISCO-LWAPP-CCX-RM-MIB
1.3.6.1.4.1.9.9.520.1.4.1clcrClientBeaconReportTableCISCO-LWAPP-CCX-RM-MIB
1.3.6.1.4.1.9.9.520.1.4.1.1clcrClientBeaconReportEntryCISCO-LWAPP-CCX-RM-MIB
1.3.6.1.4.1.9.9.520.1.4.1.1.2clcrClientRxPowerSignalCISCO-LWAPP-CCX-RM-MIB