CISCO-GPRS-CHARGING-MIB :: cgprsCgDownTimes

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-GPRS-CHARGING-MIBcgprsCgDownTimes

cgprsCgDownTimes

Module: CISCO-GPRS-CHARGING-MIB

OID (symbolic): CISCO-GPRS-CHARGING-MIB::cgprsCgDownTimes

OID (numeric): 1.3.6.1.4.1.9.9.192.1.3.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of occurrences of cgprsCgAlarmEchoFailure traps state transitions since system startup.

Trigger Condition: This counter is incremented when the GGSN detects a CG has gone down. Condition includes, a) Link state down. b) Redirection request.

What is cgprsCgDownTimes?

This read-only counter tracks how many times the GGSN has detected a Charging Gateway going down (e.g. due to link state down or redirection) since system startup.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.192.1.3.1
snmpwalk -v2c -c public <target> CISCO-GPRS-CHARGING-MIB::cgprsCgDownTimes

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.192.1.3.1.1
snmpget -v2c -c public <target> CISCO-GPRS-CHARGING-MIB::cgprsCgDownTimes.1

Start monitoring Cisco GGSN (Gateway GPRS Support Node) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-GPRS-CHARGING-MIB::cgprsCgDownTimes OID value, configure state conditions and alerts, and monitor any Cisco GGSN (Gateway GPRS Support Node) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco GGSN (Gateway GPRS Support Node) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cgprsCgDownTimes into the Find box to locate it in the OID tree, then select it and click OK. The number of occurrences of cgprsCgAlarmEchoFailure traps state transitions since system startup. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.192ciscoGprsChargingMIBCISCO-GPRS-CHARGING-MIB
1.3.6.1.4.1.9.9.192.1ciscoGprsChargingMIBObjectsCISCO-GPRS-CHARGING-MIB
1.3.6.1.4.1.9.9.192.1.3ciscoGprsChargingStatsCISCO-GPRS-CHARGING-MIB
1.3.6.1.4.1.9.9.192.1.3.1cgprsCgDownTimesCISCO-GPRS-CHARGING-MIB