CISCO-FIREPOWER-BIOS-MIB :: cfprBiosVfPCISlotOptionROMEnableVpSlot7State

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-FIREPOWER-BIOS-MIBcfprBiosVfPCISlotOptionROMEnableVpSlot7State

cfprBiosVfPCISlotOptionROMEnableVpSlot7State

Module: CISCO-FIREPOWER-BIOS-MIB

OID (symbolic): CISCO-FIREPOWER-BIOS-MIB::cfprBiosVfPCISlotOptionROMEnableVpSlot7State

OID (numeric): 1.3.6.1.4.1.9.9.826.1.5.50.1.16

Node type: OBJECT-TYPE

Type: CfprBiosVfPCISlotOptionROMEnableVpSlot7State

Access: read-only

Description: Cisco Firepower bios:VfPCISlotOptionROMEnable:vpSlot7State managed object property

What is cfprBiosVfPCISlotOptionROMEnableVpSlot7State?

Reports the configured state (enabled/disabled) of the Option ROM for PCI slot 7 in a Cisco Firepower BIOS policy's virtual profile, controlling whether that slot's device firmware initializes at boot.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.826.1.5.50.1.16
snmpwalk -v2c -c public <target> CISCO-FIREPOWER-BIOS-MIB::cfprBiosVfPCISlotOptionROMEnableVpSlot7State

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.826.1.5.50.1.16.1
snmpget -v2c -c public <target> CISCO-FIREPOWER-BIOS-MIB::cfprBiosVfPCISlotOptionROMEnableVpSlot7State.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cfprBiosVfPCISlotOptionROMEnableVpSlot7State.1

Start monitoring Cisco Firepower FXOS chassis platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-FIREPOWER-BIOS-MIB::cfprBiosVfPCISlotOptionROMEnableVpSlot7State OID value, configure state conditions and alerts, and monitor any Cisco Firepower FXOS chassis platforms from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.826ciscoFirepowerMIBCISCO-FIREPOWER-MIB
1.3.6.1.4.1.9.9.826.1ciscoFirepowerMIBObjectsCISCO-FIREPOWER-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.826.1.5cfprBiosObjectsCISCO-FIREPOWER-BIOS-MIB
1.3.6.1.4.1.9.9.826.1.5.50cfprBiosVfPCISlotOptionROMEnableTableCISCO-FIREPOWER-BIOS-MIB
1.3.6.1.4.1.9.9.826.1.5.50.1cfprBiosVfPCISlotOptionROMEnableEntryCISCO-FIREPOWER-BIOS-MIB
1.3.6.1.4.1.9.9.826.1.5.50.1.16cfprBiosVfPCISlotOptionROMEnableVpSlot7StateCISCO-FIREPOWER-BIOS-MIB