CISCO-FIREPOWER-ADAPTOR-MIB :: cfprAdaptorMenloBaseErrorStatsHistUncorrectableErrorsDeltaAvg

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-FIREPOWER-ADAPTOR-MIBcfprAdaptorMenloBaseErrorStatsHistUncorrectableErrorsDeltaAvg

cfprAdaptorMenloBaseErrorStatsHistUncorrectableErrorsDeltaAvg

Module: CISCO-FIREPOWER-ADAPTOR-MIB

OID (symbolic): CISCO-FIREPOWER-ADAPTOR-MIB::cfprAdaptorMenloBaseErrorStatsHistUncorrectableErrorsDeltaAvg

OID (numeric): 1.3.6.1.4.1.9.9.826.1.3.83.1.16

Node type: OBJECT-TYPE

Type: Unsigned64

Access: read-only

Description: Cisco Firepower adaptor:MenloBaseErrorStatsHist:uncorrectableErro rsDeltaAvg managed object property

What is cfprAdaptorMenloBaseErrorStatsHistUncorrectableErrorsDeltaAvg?

Reports the average rate of change in uncorrectable errors on the Menlo adaptor across the historical sampling intervals.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.826.1.3.83.1.16
snmpwalk -v2c -c public <target> CISCO-FIREPOWER-ADAPTOR-MIB::cfprAdaptorMenloBaseErrorStatsHistUncorrectableErrorsDeltaAvg

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.826.1.3.83.1.16.1
snmpget -v2c -c public <target> CISCO-FIREPOWER-ADAPTOR-MIB::cfprAdaptorMenloBaseErrorStatsHistUncorrectableErrorsDeltaAvg.1

Start monitoring Cisco Firepower security appliances with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-FIREPOWER-ADAPTOR-MIB::cfprAdaptorMenloBaseErrorStatsHistUncorrectableErrorsDeltaAvg OID value, configure state conditions and alerts, and monitor any Cisco Firepower security appliances from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
1.3.6.1.4.1.9.9.826ciscoFirepowerMIBCISCO-FIREPOWER-MIB
1.3.6.1.4.1.9.9.826.1ciscoFirepowerMIBObjectsCISCO-FIREPOWER-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9.9.826.1.3cfprAdaptorObjectsCISCO-FIREPOWER-ADAPTOR-MIB
1.3.6.1.4.1.9.9.826.1.3.83cfprAdaptorMenloBaseErrorStatsHistTableCISCO-FIREPOWER-ADAPTOR-MIB
1.3.6.1.4.1.9.9.826.1.3.83.1cfprAdaptorMenloBaseErrorStatsHistEntryCISCO-FIREPOWER-ADAPTOR-MIB
1.3.6.1.4.1.9.9.826.1.3.83.1.16cfprAdaptorMenloBaseErrorStatsHistUncorrectableErrorsDeltaAvgCISCO-FIREPOWER-ADAPTOR-MIB