All MIBs › CISCO-ENTITY-FRU-CONTROL-MIB › cefcPowerNonRedundantReason
cefcPowerNonRedundantReason
Module: CISCO-ENTITY-FRU-CONTROL-MIB
OID (symbolic): CISCO-ENTITY-FRU-CONTROL-MIB::cefcPowerNonRedundantReason
OID (numeric): 1.3.6.1.4.1.9.9.117.1.1.1.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This object has the value of notApplicable(1) when cefcPowerRedundancyOperMode of the instance does not have the value of nonRedundant(4).
The other values explain the reason why cefcPowerRedundancyOperMode is nonRedundant(4), e.g.
unknown(2) the reason is not identified.
singleSupply(3) There is only one power supply in the group.
mismatchedSupplies(4) There are more than one power supplies in the groups. However they are mismatched and can not work redundantly.
supplyError(5) Some power supply or supplies does or do not working properly.
What is cefcPowerNonRedundantReason?
Explains why the power supply system is currently operating in a non-redundant mode (e.g. insufficient power supplies), or indicates the reason is not applicable when redundancy is active.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.117.1.1.1.1.6 snmpwalk -v2c -c public <target> CISCO-ENTITY-FRU-CONTROL-MIB::cefcPowerNonRedundantReason
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.117.1.1.1.1.6.1 snmpget -v2c -c public <target> CISCO-ENTITY-FRU-CONTROL-MIB::cefcPowerNonRedundantReason.1
Start monitoring Cisco modular routers/switches (Field Replaceable Units) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-ENTITY-FRU-CONTROL-MIB::cefcPowerNonRedundantReason OID value, configure state conditions and alerts, and monitor any Cisco modular routers/switches (Field Replaceable Units) from a single console.
How to Use in IPNetwork Monitor
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.117 | ciscoEntityFRUControlMIB | CISCO-ENTITY-FRU-CONTROL-MIB |
| 1.3.6.1.4.1.9.9.117.1 | cefcMIBObjects | CISCO-ENTITY-FRU-CONTROL-MIB |
| 1.3.6.1.4.1.9.9.117.1.1 | cefcFRUPower | CISCO-ENTITY-FRU-CONTROL-MIB |
| 1.3.6.1.4.1.9.9.117.1.1.1 | cefcFRUPowerSupplyGroupTable | CISCO-ENTITY-FRU-CONTROL-MIB |
| 1.3.6.1.4.1.9.9.117.1.1.1.1 | cefcFRUPowerSupplyGroupEntry | CISCO-ENTITY-FRU-CONTROL-MIB |
| 1.3.6.1.4.1.9.9.117.1.1.1.1.6 | cefcPowerNonRedundantReason | CISCO-ENTITY-FRU-CONTROL-MIB |