CISCO-ENTITY-FRU-CONTROL-MIB :: cefcPowerNonRedundantReason

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-ENTITY-FRU-CONTROL-MIBcefcPowerNonRedundantReason

cefcPowerNonRedundantReason

Module: CISCO-ENTITY-FRU-CONTROL-MIB

OID (symbolic): CISCO-ENTITY-FRU-CONTROL-MIB::cefcPowerNonRedundantReason

OID (numeric): 1.3.6.1.4.1.9.9.117.1.1.1.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object has the value of notApplicable(1) when cefcPowerRedundancyOperMode of the instance does not have the value of nonRedundant(4).

The other values explain the reason why cefcPowerRedundancyOperMode is nonRedundant(4), e.g.

unknown(2) the reason is not identified.

singleSupply(3) There is only one power supply in the group.

mismatchedSupplies(4) There are more than one power supplies in the groups. However they are mismatched and can not work redundantly.

supplyError(5) Some power supply or supplies does or do not working properly.

What is cefcPowerNonRedundantReason?

Explains why the power supply system is currently operating in a non-redundant mode (e.g. insufficient power supplies), or indicates the reason is not applicable when redundancy is active.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.117.1.1.1.1.6
snmpwalk -v2c -c public <target> CISCO-ENTITY-FRU-CONTROL-MIB::cefcPowerNonRedundantReason

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.117.1.1.1.1.6.1
snmpget -v2c -c public <target> CISCO-ENTITY-FRU-CONTROL-MIB::cefcPowerNonRedundantReason.1

Start monitoring Cisco modular routers/switches (Field Replaceable Units) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-ENTITY-FRU-CONTROL-MIB::cefcPowerNonRedundantReason OID value, configure state conditions and alerts, and monitor any Cisco modular routers/switches (Field Replaceable Units) from a single console.

How to Use in IPNetwork Monitor

Select a Cisco modular routers/switch (Field Replaceable Units) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type cefcPowerNonRedundantReason into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This object has the value of notApplicable(1) when cefcPowerRedundancyOperMode of the instance does not have the value of nonRedundant(4). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is 'mismatchedSupplies' or 'supplyError', since those indicate a hardware fault rather than an expected single-supply or not-applicable configuration. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.117ciscoEntityFRUControlMIBCISCO-ENTITY-FRU-CONTROL-MIB
1.3.6.1.4.1.9.9.117.1cefcMIBObjectsCISCO-ENTITY-FRU-CONTROL-MIB
1.3.6.1.4.1.9.9.117.1.1cefcFRUPowerCISCO-ENTITY-FRU-CONTROL-MIB
1.3.6.1.4.1.9.9.117.1.1.1cefcFRUPowerSupplyGroupTableCISCO-ENTITY-FRU-CONTROL-MIB
1.3.6.1.4.1.9.9.117.1.1.1.1cefcFRUPowerSupplyGroupEntryCISCO-ENTITY-FRU-CONTROL-MIB
1.3.6.1.4.1.9.9.117.1.1.1.1.6cefcPowerNonRedundantReasonCISCO-ENTITY-FRU-CONTROL-MIB