CISCO-ENTITY-FRU-CONTROL-MIB :: cefcPSOutputModeInOperation

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-ENTITY-FRU-CONTROL-MIBcefcPSOutputModeInOperation

cefcPSOutputModeInOperation

Module: CISCO-ENTITY-FRU-CONTROL-MIB

OID (symbolic): CISCO-ENTITY-FRU-CONTROL-MIB::cefcPSOutputModeInOperation

OID (numeric): 1.3.6.1.4.1.9.9.117.1.6.2.1.3

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: A value of 'true' indicates that this mode is the operational mode of the power supply output capacity.

A value of 'false' indicates that this mode is not the operational mode of the power supply output capacity.

For a given power supply's entPhysicalIndex, at most one instance of this object can have the value of true(1).

What is cefcPSOutputModeInOperation?

This read-only boolean indicates whether a given output capacity mode is the one currently operational for the power supply.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.117.1.6.2.1.3
snmpwalk -v2c -c public <target> CISCO-ENTITY-FRU-CONTROL-MIB::cefcPSOutputModeInOperation

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.117.1.6.2.1.3.1
snmpget -v2c -c public <target> CISCO-ENTITY-FRU-CONTROL-MIB::cefcPSOutputModeInOperation.1

Start monitoring Cisco modular routers/switches (Field Replaceable Units) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-ENTITY-FRU-CONTROL-MIB::cefcPSOutputModeInOperation OID value, configure state conditions and alerts, and monitor any Cisco modular routers/switches (Field Replaceable Units) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9ciscoCAT2600-MIB
1.3.6.1.4.1.9.9ciscoMgmtCISCO-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9.9.117ciscoEntityFRUControlMIBCISCO-ENTITY-FRU-CONTROL-MIB
1.3.6.1.4.1.9.9.117.1cefcMIBObjectsCISCO-ENTITY-FRU-CONTROL-MIB
1.3.6.1.4.1.9.9.117.1.6cefcPowerCapacityCISCO-ENTITY-FRU-CONTROL-MIB
1.3.6.1.4.1.9.9.117.1.6.2cefcPowerSupplyOutputTableCISCO-ENTITY-FRU-CONTROL-MIB
1.3.6.1.4.1.9.9.117.1.6.2.1cefcPowerSupplyOutputEntryCISCO-ENTITY-FRU-CONTROL-MIB
1.3.6.1.4.1.9.9.117.1.6.2.1.3cefcPSOutputModeInOperationCISCO-ENTITY-FRU-CONTROL-MIB