All MIBs › CISCO-ENTITY-FRU-CONTROL-MIB › cefcModuleResetReasonDescription
cefcModuleResetReasonDescription
Module: CISCO-ENTITY-FRU-CONTROL-MIB
OID (symbolic): CISCO-ENTITY-FRU-CONTROL-MIB::cefcModuleResetReasonDescription
OID (numeric): 1.3.6.1.4.1.9.9.117.1.2.1.1.6
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: A description qualifying the module reset reason specified in cefcModuleResetReason.
Examples: command xyz missing task switch over watchdog timeout etc.
cefcModuleResetReasonDescription is for display purposes only. NMS applications must not parse.
What is cefcModuleResetReasonDescription?
This read-only value provides a human-readable text description elaborating on the module's last reset reason, such as a command, missing task, switchover, or watchdog timeout.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9.9.117.1.2.1.1.6 snmpwalk -v2c -c public <target> CISCO-ENTITY-FRU-CONTROL-MIB::cefcModuleResetReasonDescription
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.9.9.117.1.2.1.1.6.1 snmpget -v2c -c public <target> CISCO-ENTITY-FRU-CONTROL-MIB::cefcModuleResetReasonDescription.1
Start monitoring Cisco modular routers/switches (Field Replaceable Units) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-ENTITY-FRU-CONTROL-MIB::cefcModuleResetReasonDescription OID value, configure state conditions and alerts, and monitor any Cisco modular routers/switches (Field Replaceable Units) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.9 | cisco | CAT2600-MIB |
| 1.3.6.1.4.1.9.9 | ciscoMgmt | CISCO-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.9.9.117 | ciscoEntityFRUControlMIB | CISCO-ENTITY-FRU-CONTROL-MIB |
| 1.3.6.1.4.1.9.9.117.1 | cefcMIBObjects | CISCO-ENTITY-FRU-CONTROL-MIB |
| 1.3.6.1.4.1.9.9.117.1.2 | cefcModule | CISCO-ENTITY-FRU-CONTROL-MIB |
| 1.3.6.1.4.1.9.9.117.1.2.1 | cefcModuleTable | CISCO-ENTITY-FRU-CONTROL-MIB |
| 1.3.6.1.4.1.9.9.117.1.2.1.1 | cefcModuleEntry | CISCO-ENTITY-FRU-CONTROL-MIB |
| 1.3.6.1.4.1.9.9.117.1.2.1.1.6 | cefcModuleResetReasonDescription | CISCO-ENTITY-FRU-CONTROL-MIB |