All MIBs › CIENA-CES-TIME-SYNC-MIB › cienaCesOutputTimingInterfaceProtocol
cienaCesOutputTimingInterfaceProtocol
Module: CIENA-CES-TIME-SYNC-MIB
OID (symbolic): CIENA-CES-TIME-SYNC-MIB::cienaCesOutputTimingInterfaceProtocol
OID (numeric): 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.4
Node type: OBJECT-TYPE
Type: SyncInterfaceProtocol
Access: read-only
Description: The interface protocol of this output reference.
What is cienaCesOutputTimingInterfaceProtocol?
This reports which timing-distribution protocol this specific output interface uses to hand off the recovered clock to downstream equipment, which the admin must confirm matches what the downstream device expects to receive. For example, an output configured to distribute timing via a T1/E1 framed signal wouldn't successfully feed a downstream device expecting a synchronous Ethernet timing signal, even though the physical cabling might be correct.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.4 snmpwalk -v2c -c public <target> CIENA-CES-TIME-SYNC-MIB::cienaCesOutputTimingInterfaceProtocol
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.4.1 snmpget -v2c -c public <target> CIENA-CES-TIME-SYNC-MIB::cienaCesOutputTimingInterfaceProtocol.1
Start monitoring Ciena Carrier Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-TIME-SYNC-MIB::cienaCesOutputTimingInterfaceProtocol OID value, configure state conditions and alerts, and monitor any Ciena Carrier Ethernet switches from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.1 | cienaCesConfig | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.1.28 | cienaCesTimeSyncMIB | CIENA-CES-TIME-SYNC-MIB |
| 1.3.6.1.4.1.1271.2.1.28.1 | cienaCesTimeSyncMIBObjects | CIENA-CES-TIME-SYNC-MIB |
| 1.3.6.1.4.1.1271.2.1.28.1.1 | cienaCesTimeSyncObjects | CIENA-CES-TIME-SYNC-MIB |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7 | cienaCesSyncOutputTable | CIENA-CES-TIME-SYNC-MIB |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1 | cienaCesSyncOutputEntry | CIENA-CES-TIME-SYNC-MIB |
| 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.4 | cienaCesOutputTimingInterfaceProtocol | CIENA-CES-TIME-SYNC-MIB |