CIENA-CES-TIME-SYNC-MIB :: cienaCesOutputTimingInterfaceName

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-TIME-SYNC-MIB › cienaCesOutputTimingInterfaceName

cienaCesOutputTimingInterfaceName

Module: CIENA-CES-TIME-SYNC-MIB

OID (symbolic): CIENA-CES-TIME-SYNC-MIB::cienaCesOutputTimingInterfaceName

OID (numeric): 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.3

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: The interface name of this output reference.

What is cienaCesOutputTimingInterfaceName?

This reports the physical interface name through which this device outputs its recovered timing signal to downstream equipment, letting an admin map a downstream device's clock problems back to the specific local output port responsible for feeding it. For example, if a downstream switch reports it isn't receiving a stable timing signal, this object tells the admin exactly which local output interface to check first.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.3
snmpwalk -v2c -c public <target> CIENA-CES-TIME-SYNC-MIB::cienaCesOutputTimingInterfaceName

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.28.1.1.7.1.3.1
snmpget -v2c -c public <target> CIENA-CES-TIME-SYNC-MIB::cienaCesOutputTimingInterfaceName.1

Start monitoring Ciena Carrier Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-TIME-SYNC-MIB::cienaCesOutputTimingInterfaceName OID value, configure state conditions and alerts, and monitor any Ciena Carrier Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.28cienaCesTimeSyncMIBCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1cienaCesTimeSyncMIBObjectsCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1cienaCesTimeSyncObjectsCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1.7cienaCesSyncOutputTableCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1.7.1cienaCesSyncOutputEntryCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1.7.1.3cienaCesOutputTimingInterfaceNameCIENA-CES-TIME-SYNC-MIB