CIENA-CES-TIME-SYNC-MIB :: cienaCesInputPUBITSSignalMode

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-TIME-SYNC-MIB › cienaCesInputPUBITSSignalMode

cienaCesInputPUBITSSignalMode

Module: CIENA-CES-TIME-SYNC-MIB

OID (symbolic): CIENA-CES-TIME-SYNC-MIB::cienaCesInputPUBITSSignalMode

OID (numeric): 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.12

Node type: OBJECT-TYPE

Type: SyncBITSSignalMode

Access: read-only

Description: BITS Signal Mode, set if BITS signal is used as a protection unit.

What is cienaCesInputPUBITSSignalMode?

This reports the configured signaling mode, a BITS-specific electrical/framing parameter, for this reference unit, and per the description is only meaningful when this particular unit is actually a BITS feed rather than some other reference type like GPS. An admin troubleshooting a BITS-fed unit that isn't achieving lock should verify this mode setting matches what the upstream BITS clock is actually configured to send, since a mode mismatch is a common cause of a physically-connected but unusable BITS reference. For example, this object being set incorrectly relative to the upstream source's actual output mode would prevent the receiving equipment from properly decoding the timing signal even though cabling is intact.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.12
snmpwalk -v2c -c public <target> CIENA-CES-TIME-SYNC-MIB::cienaCesInputPUBITSSignalMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.28.1.1.6.1.12.1
snmpget -v2c -c public <target> CIENA-CES-TIME-SYNC-MIB::cienaCesInputPUBITSSignalMode.1

Start monitoring Ciena Carrier Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-TIME-SYNC-MIB::cienaCesInputPUBITSSignalMode OID value, configure state conditions and alerts, and monitor any Ciena Carrier Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.28cienaCesTimeSyncMIBCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1cienaCesTimeSyncMIBObjectsCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1cienaCesTimeSyncObjectsCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1.6cienaCesSyncInputProtectionUnitTableCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1.6.1cienaCesSyncInputProtectionUnitEntryCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1.6.1.12cienaCesInputPUBITSSignalModeCIENA-CES-TIME-SYNC-MIB