CIENA-CES-TIME-SYNC-MIB :: cienaCesInputPGSelectedReference

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CIENA-CES-TIME-SYNC-MIB › cienaCesInputPGSelectedReference

cienaCesInputPGSelectedReference

Module: CIENA-CES-TIME-SYNC-MIB

OID (symbolic): CIENA-CES-TIME-SYNC-MIB::cienaCesInputPGSelectedReference

OID (numeric): 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.4

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: System selected timing reference source.

What is cienaCesInputPGSelectedReference?

This reports which specific timing reference source the system is actually using right now for this protection group, as determined automatically by the clock-selection algorithm based on availability, configured priority, and received quality level, as opposed to cienaCesInputPGPreferredReference, which only records what the admin wanted. An admin monitoring this value in real time can detect a reference switchover the moment it happens, often before any alarm fires, by seeing this string change from the expected preferred source to a fallback source. For example, this value flipping from 'BITS-1' to 'GPS-2' during a maintenance window on the BITS feed confirms the failover worked as designed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.4
snmpwalk -v2c -c public <target> CIENA-CES-TIME-SYNC-MIB::cienaCesInputPGSelectedReference

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.28.1.1.5.1.4.1
snmpget -v2c -c public <target> CIENA-CES-TIME-SYNC-MIB::cienaCesInputPGSelectedReference.1

Start monitoring Ciena Carrier Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-TIME-SYNC-MIB::cienaCesInputPGSelectedReference OID value, configure state conditions and alerts, and monitor any Ciena Carrier Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.28cienaCesTimeSyncMIBCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1cienaCesTimeSyncMIBObjectsCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1cienaCesTimeSyncObjectsCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1.5cienaCesSyncInputProtectionGroupTableCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1.5.1cienaCesSyncInputProtectionGroupEntryCIENA-CES-TIME-SYNC-MIB
1.3.6.1.4.1.1271.2.1.28.1.1.5.1.4cienaCesInputPGSelectedReferenceCIENA-CES-TIME-SYNC-MIB