CIENA-CES-RADIUS-CLIENT-MIB :: cienaCesRadiusUserLoginResolvedInetAddrType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-RADIUS-CLIENT-MIBcienaCesRadiusUserLoginResolvedInetAddrType

cienaCesRadiusUserLoginResolvedInetAddrType

Module: CIENA-CES-RADIUS-CLIENT-MIB

OID (symbolic): CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusUserLoginResolvedInetAddrType

OID (numeric): 1.3.6.1.4.1.1271.2.3.3.1.1.3.2.1.2

Node type: OBJECT-TYPE

Type: InetAddressType

Access: read-only

Description: Specifies the resolved IP address type. This OID is used in conjunction with cienaCesRadiusUserLoginInetAddrress. When set to : ipv4 : cienaCesRadiusUserLoginResolvedInetAddress should be compliant with InetAddressIPv4 ipv6 : cienaCesRadiusUserLoginResolvedInetAddress should be compliant with InetAddressIPv6

What is cienaCesRadiusUserLoginResolvedInetAddrType?

This tells the admin whether the dedicated user-login RADIUS server's resolved address is IPv4 or IPv6, a capability the base RADIUS client table's plain IpAddress-typed resolved-address object does not support. That means the user-login table was specifically built to accommodate a dual-stack network that the older base table cannot represent. For example, seeing 'ipv6' here would tell the admin their login-authentication RADIUS server was reached over IPv6, a scenario the legacy base client table's IPv4-only address object couldn't have represented.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.3.1.1.3.2.1.2
snmpwalk -v2c -c public <target> CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusUserLoginResolvedInetAddrType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.3.1.1.3.2.1.2.1
snmpget -v2c -c public <target> CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusUserLoginResolvedInetAddrType.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusUserLoginResolvedInetAddrType OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.3cienaCesRadiusClientMIBCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1cienaCesRadiusClientMIBObjectsCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1cienaCesRadiusClientCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.3cienaCesRadiusUserLoginCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.3.2cienaCesRadiusUserLoginTableCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.3.2.1cienaCesRadiusUserLoginEntryCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.3.2.1.2cienaCesRadiusUserLoginResolvedInetAddrTypeCIENA-CES-RADIUS-CLIENT-MIB