CIENA-CES-RADIUS-CLIENT-MIB :: cienaCesRadiusDot1xAuthMalformedResponses

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-RADIUS-CLIENT-MIBcienaCesRadiusDot1xAuthMalformedResponses

cienaCesRadiusDot1xAuthMalformedResponses

Module: CIENA-CES-RADIUS-CLIENT-MIB

OID (symbolic): CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAuthMalformedResponses

OID (numeric): 1.3.6.1.4.1.1271.2.3.3.1.1.4.2.1.16

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of malformed RADIUS Access-Response packets received from this server. Malformed packets include packets with an invalid length. Bad authenticators or signature attributes or unknown types are not included as malformed access responses.

What is cienaCesRadiusDot1xAuthMalformedResponses?

This counts RADIUS responses from this server that were structurally malformed, specifically ones with an invalid length, explicitly excluding bad authenticators, signature problems, and unknown packet types, which are tracked by separate counters. Because the definition narrows this to length errors, a nonzero and climbing value here points an admin specifically at a truncation or MTU issue between the switch and this RADIUS server rather than a credentials or shared-secret problem. For example, if this counter starts incrementing right after a network team enables a new firewall ACL on the RADIUS server's subnet, the firewall is a more likely suspect than the RADIUS server's own configuration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.3.1.1.4.2.1.16
snmpwalk -v2c -c public <target> CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAuthMalformedResponses

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.3.1.1.4.2.1.16.1
snmpget -v2c -c public <target> CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAuthMalformedResponses.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAuthMalformedResponses OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.3cienaCesRadiusClientMIBCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1cienaCesRadiusClientMIBObjectsCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1cienaCesRadiusClientCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.4cienaCesRadiusDot1xAuthCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.4.2cienaCesRadiusDot1xAuthTableCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.4.2.1cienaCesRadiusDot1xAuthEntryCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.4.2.1.16cienaCesRadiusDot1xAuthMalformedResponsesCIENA-CES-RADIUS-CLIENT-MIB