All MIBs › CIENA-CES-RADIUS-CLIENT-MIB › cienaCesRadiusDot1xAcctResolvedInetAddress
cienaCesRadiusDot1xAcctResolvedInetAddress
Module: CIENA-CES-RADIUS-CLIENT-MIB
OID (symbolic): CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAcctResolvedInetAddress
OID (numeric): 1.3.6.1.4.1.1271.2.3.3.1.1.5.2.1.3
Node type: OBJECT-TYPE
Type: InetAddress
Access: read-only
Description: Specifies the resolved IP address if cienaCesRadiusDot1xAcctAddr is set to host name. If cienaCesRadiusDot1xAcctAddr is set to ip address then cienaCesRadiusDot1xAcctResolvedInetAddress will contain same information as cienaCesRadiusDot1xAcctAddr. This OID should be used in conjuction with cienaCesRadiusDot1xAcctResolvedInetAddrType.
What is cienaCesRadiusDot1xAcctResolvedInetAddress?
This holds the actual resolved IP address the switch uses to reach the 802.1X accounting server, whether the Addr object was configured as a hostname or a literal IP. An admin should check this object rather than trusting the configured hostname when accounting records stop arriving, since a stale or changed DNS entry can point the switch's accounting traffic at a different, unintended host. For example, if the accounting server hostname acct-radius.corp.local gets re-pointed during a server migration, this object reflects the newly resolved address immediately, even before anyone updates documentation.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.3.1.1.5.2.1.3 snmpwalk -v2c -c public <target> CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAcctResolvedInetAddress
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.3.1.1.5.2.1.3.1 snmpget -v2c -c public <target> CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAcctResolvedInetAddress.1
Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAcctResolvedInetAddress OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.3 | cienaCesStatistics | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.3.3 | cienaCesRadiusClientMIB | CIENA-CES-RADIUS-CLIENT-MIB |
| 1.3.6.1.4.1.1271.2.3.3.1 | cienaCesRadiusClientMIBObjects | CIENA-CES-RADIUS-CLIENT-MIB |
| 1.3.6.1.4.1.1271.2.3.3.1.1 | cienaCesRadiusClient | CIENA-CES-RADIUS-CLIENT-MIB |
| 1.3.6.1.4.1.1271.2.3.3.1.1.5 | cienaCesRadiusDot1xAcct | CIENA-CES-RADIUS-CLIENT-MIB |
| 1.3.6.1.4.1.1271.2.3.3.1.1.5.2 | cienaCesRadiusDot1xAcctTable | CIENA-CES-RADIUS-CLIENT-MIB |
| 1.3.6.1.4.1.1271.2.3.3.1.1.5.2.1 | cienaCesRadiusDot1xAcctEntry | CIENA-CES-RADIUS-CLIENT-MIB |
| 1.3.6.1.4.1.1271.2.3.3.1.1.5.2.1.3 | cienaCesRadiusDot1xAcctResolvedInetAddress | CIENA-CES-RADIUS-CLIENT-MIB |