CIENA-CES-RADIUS-CLIENT-MIB :: cienaCesRadiusDot1xAcctResolvedInetAddrType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-RADIUS-CLIENT-MIBcienaCesRadiusDot1xAcctResolvedInetAddrType

cienaCesRadiusDot1xAcctResolvedInetAddrType

Module: CIENA-CES-RADIUS-CLIENT-MIB

OID (symbolic): CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAcctResolvedInetAddrType

OID (numeric): 1.3.6.1.4.1.1271.2.3.3.1.1.5.2.1.2

Node type: OBJECT-TYPE

Type: InetAddressType

Access: read-only

Description: Specifies the resolved IP address type. This OID is used in conjunction with cienaCesRadiusDot1xAcctInetAddrress. When set to : ipv4 : cienaCesRadiusDot1xAcctResolvedInetAddress should be compliant with InetAddressIPv4 ipv6 : cienaCesRadiusDot1xAcctResolvedInetAddress should be compliant with InetAddressIPv6

What is cienaCesRadiusDot1xAcctResolvedInetAddrType?

This reports whether the accounting server address resolved from the configured Addr object is IPv4 or IPv6. This lets an admin confirm which IP family the switch is actually using to deliver accounting records when the server was configured by hostname, which matters if the accounting server or a firewall in front of it only listens on one address family. For example, if a dual-stack DNS record for the accounting server flips to prefer AAAA after a network change, this object switching from ipv4(1) to ipv6(2) would explain accounting traffic suddenly needing IPv6 reachability that wasn't required before.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.3.1.1.5.2.1.2
snmpwalk -v2c -c public <target> CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAcctResolvedInetAddrType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.3.1.1.5.2.1.2.1
snmpget -v2c -c public <target> CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAcctResolvedInetAddrType.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-RADIUS-CLIENT-MIB::cienaCesRadiusDot1xAcctResolvedInetAddrType OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.3cienaCesRadiusClientMIBCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1cienaCesRadiusClientMIBObjectsCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1cienaCesRadiusClientCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.5cienaCesRadiusDot1xAcctCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.5.2cienaCesRadiusDot1xAcctTableCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.5.2.1cienaCesRadiusDot1xAcctEntryCIENA-CES-RADIUS-CLIENT-MIB
1.3.6.1.4.1.1271.2.3.3.1.1.5.2.1.2cienaCesRadiusDot1xAcctResolvedInetAddrTypeCIENA-CES-RADIUS-CLIENT-MIB