All MIBs › CIENA-CES-PORT-XCVR-MIB › cienaCesPortXcvrHighVccAlarmThreshold
cienaCesPortXcvrHighVccAlarmThreshold
Module: CIENA-CES-PORT-XCVR-MIB
OID (symbolic): CIENA-CES-PORT-XCVR-MIB::cienaCesPortXcvrHighVccAlarmThreshold
OID (numeric): 1.3.6.1.4.1.1271.2.1.9.1.1.1.1.9
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Indicates the higher threshold for the voltage alarm. Units are milli volts
What is cienaCesPortXcvrHighVccAlarmThreshold?
This is the configured ceiling the live Vcc reading is compared against, so an admin investigating why a specific transceiver's voltage alarm fired should compare the live cienaCesPortXcvrVcc value against exactly this number rather than assuming a generic 3.3V-nominal rule applies uniformly across every optic model in the chassis. For example, a threshold of 3465 millivolts on a 3.3V-nominal optic allows roughly 5% headroom above nominal before alarming.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.9.1.1.1.1.9 snmpwalk -v2c -c public <target> CIENA-CES-PORT-XCVR-MIB::cienaCesPortXcvrHighVccAlarmThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.9.1.1.1.1.9.1 snmpget -v2c -c public <target> CIENA-CES-PORT-XCVR-MIB::cienaCesPortXcvrHighVccAlarmThreshold.1
Start monitoring Ciena CES switch port optics (SFP/XFP) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PORT-XCVR-MIB::cienaCesPortXcvrHighVccAlarmThreshold OID value, configure state conditions and alerts, and monitor any Ciena CES switch port optics (SFP/XFP) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.1 | cienaCesConfig | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.1.9 | cienaCesPortXcvrMIB | CIENA-CES-PORT-XCVR-MIB |
| 1.3.6.1.4.1.1271.2.1.9.1 | cienaCesPortXcvrMIBObjects | CIENA-CES-PORT-XCVR-MIB |
| 1.3.6.1.4.1.1271.2.1.9.1.1 | cienaCesPortXcvr | CIENA-CES-PORT-XCVR-MIB |
| 1.3.6.1.4.1.1271.2.1.9.1.1.1 | cienaCesPortXcvrTable | CIENA-CES-PORT-XCVR-MIB |
| 1.3.6.1.4.1.1271.2.1.9.1.1.1.1 | cienaCesPortXcvrEntry | CIENA-CES-PORT-XCVR-MIB |
| 1.3.6.1.4.1.1271.2.1.9.1.1.1.1.9 | cienaCesPortXcvrHighVccAlarmThreshold | CIENA-CES-PORT-XCVR-MIB |