CIENA-CES-PM :: cienaCesPmTdmOCnPortStatisticsBinSefss

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmTdmOCnPortStatisticsBinSefss

cienaCesPmTdmOCnPortStatisticsBinSefss

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmTdmOCnPortStatisticsBinSefss

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.16.5.1.12

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Section, Severely errored frame seconds.

What is cienaCesPmTdmOCnPortStatisticsBinSefss?

This counts Section-layer Severely Errored Frame Seconds on this SONET/SDH port: seconds during which the receiver actually lost frame alignment at the Section layer, per the MIB's description. SEFSS is the most severe Section-layer counter for this port -- an out-of-frame condition at this level almost always means a hard physical event (fiber cut, connector pulled, laser fault) rather than ordinary noise, so any nonzero value in this specific bin is treated as a real fault, not just degraded margin; this particular bin is a live counter that keeps accumulating until it is explicitly cleared rather than rolling over on a fixed schedule, so a large value mostly reflects how long it has been since the last clear. A count of 3 SEFSS for this bin would typically be cross-checked against this port's physical alarm log for a matching loss-of-signal or loss-of-frame event at the same timestamp.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.16.5.1.12
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmTdmOCnPortStatisticsBinSefss

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.16.5.1.12.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmTdmOCnPortStatisticsBinSefss.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmTdmOCnPortStatisticsBinSefss OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16cienaCesPmTdmOCnPortStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16.5cienaCesPmTdmOCnPortStatisticsBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16.5.1cienaCesPmTdmOCnPortStatisticsBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16.5.1.12cienaCesPmTdmOCnPortStatisticsBinSefssCIENA-CES-PM