cienaCesPmTdmOCnPortCurrBinSesl

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmTdmOCnPortCurrBinSesl

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.16.2.1.7

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Line, Severely errored seconds.

What is cienaCesPmTdmOCnPortCurrBinSesl?

This counts Line-layer Severely Errored Seconds on this SONET/SDH port: seconds where the Line-layer error rate crossed the severe threshold during the bin, per the MIB's description. SESL is the number that actually feeds SONET Line-layer SLA calculations for this port -- unlike plain ESL it means the Line signal was briefly unusable, not just imperfect, so even a small nonzero count here in a single bin is treated as a real service-affecting event; because this bin is the still-open, currently-accumulating interval, its value is only a partial count until the bin's Duration elapses and it rolls into history -- polling it twice a few minutes apart is the fastest way to catch a fault building up in near real time. A value of 2 for this bin would be enough to trigger a carrier's SLA review process for this Line, whereas a string of zero-valued bins is the expected baseline for this port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.16.2.1.7
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmTdmOCnPortCurrBinSesl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.16.2.1.7.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmTdmOCnPortCurrBinSesl.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmTdmOCnPortCurrBinSesl OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16cienaCesPmTdmOCnPortStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16.2cienaCesPmTdmOCnPortCurrBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16.2.1cienaCesPmTdmOCnPortCurrBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16.2.1.7cienaCesPmTdmOCnPortCurrBinSeslCIENA-CES-PM