CIENA-CES-PM :: cienaCesPmTdmOCnPortCurr24HBinLoss

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmTdmOCnPortCurr24HBinLoss

cienaCesPmTdmOCnPortCurr24HBinLoss

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmTdmOCnPortCurr24HBinLoss

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.16.3.1.12

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Section, Loss of signal seconds.

What is cienaCesPmTdmOCnPortCurr24HBinLoss?

This counts Section-layer Loss of Signal seconds on this SONET/SDH port: seconds during the bin in which no usable optical signal was being received at the Section layer, per the MIB's description. LOS on this port is as close to 'the fiber went dark' as a PM counter gets -- any nonzero value in this specific bin means the receiver had literally no signal to lock onto for that many seconds, which is categorically more serious than any error-rate counter and usually correlates with a fiber cut, unplugged patch, or failed transmitter somewhere on this path; because this bin spans the whole current day and is still open, short error bursts get averaged into a slower-moving daily total -- useful for spotting a low-grade, chronic problem that the 15-minute bins would report as merely noisy. Even 3 seconds of LOS recorded in this bin would normally coincide with a hard-down alarm on this port, whereas a healthy port should show 0 for every such bin.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.16.3.1.12
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmTdmOCnPortCurr24HBinLoss

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.16.3.1.12.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmTdmOCnPortCurr24HBinLoss.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cienaCesPmTdmOCnPortCurr24HBinLoss.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmTdmOCnPortCurr24HBinLoss OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16cienaCesPmTdmOCnPortStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16.3cienaCesPmTdmOCnPortCurr24HBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16.3.1cienaCesPmTdmOCnPortCurr24HBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.16.3.1.12cienaCesPmTdmOCnPortCurr24HBinLossCIENA-CES-PM