CIENA-CES-PM :: cienaCesPmExtendedTxRxTotalStatsBinTxLCheckErrorPkts

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmExtendedTxRxTotalStatsBinTxLCheckErrorPkts

cienaCesPmExtendedTxRxTotalStatsBinTxLCheckErrorPkts

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmExtendedTxRxTotalStatsBinTxLCheckErrorPkts

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.1.7.1.26

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The number of length check error packets transmitted on the interface.

What is cienaCesPmExtendedTxRxTotalStatsBinTxLCheckErrorPkts?

This field reports the number of length check error packets transmitted on the interface, exposed here as cienaCesPmExtendedTxRxTotalStatsBinTxLCheckErrorPkts. On this Ciena CES port's PM data, this fires when the 802.3 length/type field didn't match the actual size of the frame before it left this port, i.e. a malformed frame was assembled internally rather than corrupted in transit; and this is the running grand-total counter for the extended Tx/Rx PM group, tallied since the bin's own StartTime (in practice since the PM instance was created or last reset), so treat it as a lifetime tally rather than a per-interval number. For example, a healthy port would sit at 0 for length-check-error frames in this bin; even 45 is enough to warrant a look, since this class of counter isn't supposed to move under normal operation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.1.7.1.26
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmExtendedTxRxTotalStatsBinTxLCheckErrorPkts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.1.7.1.26.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmExtendedTxRxTotalStatsBinTxLCheckErrorPkts.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmExtendedTxRxTotalStatsBinTxLCheckErrorPkts OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1cienaCesPmExtendedTxRxStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.7cienaCesPmExtendedTxRxTotalStatisticsBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.7.1cienaCesPmExtendedTxRxTotalStatisticsBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.7.1.26cienaCesPmExtendedTxRxTotalStatsBinTxLCheckErrorPktsCIENA-CES-PM