CIENA-CES-PM :: cienaCesPmExtendedTxRxTotalStatsBinRxCrcErrorPkts

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-PMcienaCesPmExtendedTxRxTotalStatsBinRxCrcErrorPkts

cienaCesPmExtendedTxRxTotalStatsBinRxCrcErrorPkts

Module: CIENA-CES-PM

OID (symbolic): CIENA-CES-PM::cienaCesPmExtendedTxRxTotalStatsBinRxCrcErrorPkts

OID (numeric): 1.3.6.1.4.1.1271.2.3.1.2.3.1.7.1.4

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: The number of packets received with CRC errors by this PM instance.

What is cienaCesPmExtendedTxRxTotalStatsBinRxCrcErrorPkts?

This field reports the number of packets received with CRC errors by this PM instance, exposed here as cienaCesPmExtendedTxRxTotalStatsBinRxCrcErrorPkts. On this Ciena CES port's PM data, a CRC/FCS mismatch means the frame's checksum didn't match its contents by the time it reached this port's MAC, which is a physical-layer signal-integrity symptom — bad cable, dirty connector, marginal optic, or a failing NIC on the far end — not a software or config issue; and this is the running grand-total counter for the extended Tx/Rx PM group, tallied since the bin's own StartTime (in practice since the PM instance was created or last reset), so treat it as a lifetime tally rather than a per-interval number. For example, a healthy port would sit at 0 for CRC-error frames in this bin; even 43 is enough to warrant a look, since this class of counter isn't supposed to move under normal operation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.1.7.1.4
snmpwalk -v2c -c public <target> CIENA-CES-PM::cienaCesPmExtendedTxRxTotalStatsBinRxCrcErrorPkts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.3.1.2.3.1.7.1.4.1
snmpget -v2c -c public <target> CIENA-CES-PM::cienaCesPmExtendedTxRxTotalStatsBinRxCrcErrorPkts.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-PM::cienaCesPmExtendedTxRxTotalStatsBinRxCrcErrorPkts OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.3cienaCesStatisticsCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.3.1cienaCesPmMibCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2cienaCesPmMIBObjectsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3cienaCesPmStatisticsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1cienaCesPmExtendedTxRxStatsCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.7cienaCesPmExtendedTxRxTotalStatisticsBinTableCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.7.1cienaCesPmExtendedTxRxTotalStatisticsBinEntryCIENA-CES-PM
1.3.6.1.4.1.1271.2.3.1.2.3.1.7.1.4cienaCesPmExtendedTxRxTotalStatsBinRxCrcErrorPktsCIENA-CES-PM